Table Of Zones; Installation - Viper 500HF Installation Manual

Auto security
Table of Contents

Advertisement

When using the Diagnostic functions, use the Table of Zones to see what input has triggered the system. It is also
helpful in deciding what input to use when connecting optional sensors and switches.
Zone #
Trigger type
One
Instant
Two
Multiplex
Three
Two-stage, progresses from
warning to full alarm
Four
Multiplex
Five
Two-stage (similar to doors)
To install the optional VRS
location and plug it into the red VRS
must be placed where it can be reached from the driver's seat. Make sure that the customer is aware of the location
of the button and is familiar with the VRS
stranded by the VRS
®
.
IMPORTANT: If the VRS
Learn Routine
section on page 18.
A few minutes are required to test the VRS
22

TABLE OF ZONES

VEHICLE RECOVERY SYSTEM
®
feature, the 8618 starter kill relay must be installed. Mount the button in a well-hidden
®
port on the control unit. Make sure it cannot be pressed accidentally. The switch
®
triggered sequence. This will ensure that the customer does not become
®
button is being installed, you must enable the VRS
. To test:
®
Open the Owner's Guide to Vehicle Recovery System
sequence is described in detail.
Press and release the VRS
Turn on the ignition and close all the doors.
Wait 15 seconds. The Status LED will begin flashing. This will be followed by chirps
and flashing lights, then by constant siren, in timed progressions described in the
Owner's Guide.
The starter kill will be turned on via the orange wire: A) if the ignition is turned off
after the chirps have stopped; or B) as soon as the siren progresses to constant
output.
IMPORTANT!: You must make sure that all users of the vehicle know how to dis
arm the VRS
®
. Remember that the remote does not affect the VRS
the user can distinguish the standard triggered response from that of the VRS
Input description
H1/6 BLUE wire. Connect to optional hood/trunk
pins.
Blue wire of plug-in shock sensor. Inputs
shorter than .8 seconds will trigger a Warn
Away
®
response, while inputs longer than .8
seconds will instantly trigger full alarm
sequence.
Door switch circuit. H1/5 GREEN or H1/7
VIOLET.
Green wire of plug-in shock sensor. Inputs
shorter than .8 seconds will trigger a Warn
Away
®
response, while inputs longer than .8
seconds will instantly trigger full alarm
sequence.
Ignition. H1/9 yellow.
The Warn Away
®
response does not report on the LED
®

INSTALLATION

®
push-button switch, with a door open.
© 1998 Directed Electronics, Inc. Vista, CA
.
®
. Refer to Operation Settings
®
section. The triggered
®
, so make sure