H1/11 RED (+)12V constant power input: Before connecting this wire, remove the supplied fuse. Connect to the
battery positive terminal or the constant 12V supply to the ignition switch as described on Page 5.
NOTE: Always use a fuse within 12 inches of the point you obtain (+)12V. Do not use the 15A fuse in the
harness for this purpose. This fuse protects the module itself.
H1/12 RED/WHITE channel 2, (-) output: When the system receives the code controlling channel, for longer than
1.5 seconds, the red/white will supply a (-) 200mA output as long as the transmission continues. This is often used
to operate a trunk/hatch release or other relay-driven function.
IMPORTANT! Never use this wire to drive anything but a relay or a low-current input! The transistorized
output can only supply 200 mA of current, connecting directly to a solenoid, motor, or other high-current
device will cause it to fail.
These plug into the module. The Status LED plugs into the small two-pin socket, while the Valet
should be plugged into the larger blue two-pin connector. The Status LED fits in a 9/32" hole.
Status LED
Green (-) Multiplex input: Inputs shorter than .8 seconds will trigger the Warn Away
than .8 seconds will trigger full alarm sequence and report zone four. If installing an optional DEI
sor, connect to the green wire as shown below. The diagram below eliminates the need for diodes to isolate the
sensors, as well as providing a seperate zone for each sensor.
Diagram for adding optional DEI
Blue (-) Multiplex input: Inputs shorter than .8 seconds will trigger the Warn Away
than .8 seconds will trigger full alarm sequence and report zone two.
Red, Black: Red is (+)12V constant, black is (-) ground. Do not use these for anything besides the plug in shock
sensor.
© 1998 Directed Electronics, Inc. Vista, CA