OPERATION INSTRUCTIONS/FLAME APPEARANCE

Flames from the pilot (rear right back side of the pan burner) as
well as the main flame should be visually checked as the log set
is installed.
In normal operation at full rate after 10 to 15 minutes, the flame
appearance should be sets of yellow flames.
NOTE: all flames will be random by design, flame height will
go up and down.
Glowing embers (rock wool) can cover the pan burner in between
the front and middle logs, but very little is necessary to cover this
area. Excess ember material causes the yellow flame to become
orange and stringy. Apply just enough to obtain slow glow and a
Manual - Figure 16
gold, yellow flame.
Avoid any drafts that alter burner flame patterns. Do not allow
fans to blow directly into fireplace. Do not place a blower inside
the burner area of the firebox. Ceiling fans may create drafts that
alter flame patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils, films
or bonding agents. These chemicals are not harmful, but may
produce annoying smoke and smells as they are burned off during
the initial operation of the appliance, possibly causing headaches
or eye or lung irritation. This is a normal and temporary
occurrence.
The initial break-in operation should last 2-3 hours with the burner
at the highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in will be slight and will disappear with
Millivolt - Figure 17
continued use.
This appliance must not be used with glass doors in the closed
position. This can lead to pilot outages and severe sooting outside
the fireplace.
Piezo Pilot Ignitor Instructions
Depressing the ignitor button completely causes a spark to occur
at the pilot.
To light the pilot, it is important that the electrode be 1/8" (3mm)
from the pilot. The spark must occur at the point the pilot flame
hits the thermocouple.
On a new installation with air in the gas line, it is suggested that
a match be used. The match will light the pilot faster than the
Modulating Hydraulic - Figure 18
piezo under this condition.