Ari Capacities - Carrier Comfort 50EZ-A Product Data

Single-packaged system with puron (r-410a) refrigerant single- and three-phase units 2 to 5 nominal tons (sizes 24-60)
Table of Contents

Advertisement

ARI* CAPACITIES
COOLING CAPACITIES AND EFFICIENCIES
UNIT 50EZ- - A
NOMINAL TONS
24- - - - - - 30
2
30- - - - - - 30/50
2- -1/2
36- - - - - - 30/50
3
42- - - - - - 30/50
3- -1/2
48- - - - - - 30/50
4
60- - - - - - 30/50
5
HEAT PUMP HEATING CAPACITIES AND EFFICIENCIES
CAPACITY (Btuh) @
UNIT 50EZ---A
24- - - - - - 30
30- - - - - - 30/50
36- - - - - - 30/50 /60
42- - - - - - 30/50/60
48- - - - - - 30/50/60
60- - - - - - 30/50/60
LEGEND
dB--- Sound Levels (decibels)
db—Dry Bulb
SEER—Seasonal Energy Efficiency Ratio
wb—Wet Bulb
COP---Coefficient of Performance
HSPF---Heating Season Performance Factor
* Air Conditioing & Refrigeration Institute.
**At "A" conditions---80_F (26.7_C) indoor db/67_F (19.4_C) indoor wb &
95_F (35_C) outdoor db.
{ Rated in accordance with U.S. Government DOE Department of Energy)
test procedures and/or ARI Standards 210/240.
STANDARD CFM
800
1000
1200
1400
1600
1850
HEATING
COP @ 47_F (8.3_C)
47_F (8.3_C)
23,400
29,000
35,000
40,000
46,500
57,000
COOLING
CAPACITIES (Btuh)
23,800
29,000
35,000
40,000
47,000
57,000
HEATING
CAPACITY (Btuh) @
17_F (---8.3_C)
3.5
10,800
3.5
15,900
3.4
20,400
3.4
22,000
3.6
26,200
3.5
31,000
Notes:
1. Ratings are net values, reflecting the effects of circulating fan heat.
Ratings are based on:
Cooling Standard: 80°F (26.7_C) db, 67°F (19.4_C) wb indoor entering---
air temperature and 95°F (35_C) db outdoor entering---air temperature.
2. Before purchasing this appliance, read important energy cost and effi-
ciency information available from your retailer.
3
EER**
SEER†
11.5
13.5
11.5
13.5
11.5
13.5
11.5
13.2
11.5
13.5
11.5
13.5
COP @
17_F
HSPF†
(---8.3_C)
2.2
7.7
2.2
7.7
2.3
7.7
2.2
7.7
2.3
7.7
2.3
7.7