TROUBLE SHOOTING CHECKLIST

Use the following chart to help determine whether a service call is required, however if you are unsure
about the way your heater is operating, contact Rinnai or your local agent.
Fault
Condition
Probable
Cause
Not plugged in or turned off.
M
a
n i
s
p
o
w
e
f r
l i a
r u
. e
(Initial Install) Air in gas pipe.
A
r i
n i
h
o
s
e
Room too large
D
u
t s
o
n
a
r i
l i f
e t
s r
Louvre obstructed
A
r i
t l i f
r e
b
o l
k c
e
d
Gas escape
G
a
s
s
u
p
p
y l
u t
n r
e
d
o
. f f
Lock set.
O
n
i T
m
r e
s i
s
e
. t
Flat batteries.

ERROR CODES

Your heater is also fitted with self diagnostic electronics that monitor the appliance during start-up and
operation. Should a fault occur the heater will shut down and the cause fault will be indicated by a pair
of flashing digits in the Digital display
indicator
will also flash Red. Refer to the table below for probable cause and the suggested
12
remedy
C
o
d
e
P
o r
00
Mains power failure during operation
03
Tilt switch activated
11
Ignition failure
12
Incomplete combustion
13
Combustion control faulty
14
Filter Blockage / Overheat
1
6
R
o
o
m
o
v
e
h r
18
Temperature sensor faulty
31
Room temperature sensor faulty
32
Overheat temperature sensor faulty
33
Overheat temperature sensor faulty
34
Overheat temperature sensor faulty
6
2
F
a
u
y t l
a f
n
m
70
ON/OFF switch faulty
7
1
S
o
e l
n
o
d i
s
a f
72
Flame detection circuit fault
73
Communication error
Operation Manual
CARE AND MAINTENANCE
or
17
b
a
b
e l
C
a
u
s
e
e
t a
t o
r o
u
y t l
Plug in power cord and turn power on.
R
- e
g i
n
t i
o i
Installer to purge air from gas supply.
R
e
p
e
t a
g I
Check with retailer.
C
e l
a
n
h t
e
Remove obstruction
C
e l
a
n
h t
e
Isolate gas supply, call Rinnai service.
T
u
n r
g
a
s
Cancel Lock as described on page 15.
C
a
n
c
e
i t l
m
Replace remote control battery.
depending on the model and the On/Combustion
31
S
u
g
g
e
s
Press the ON/OFF button
Ensure appliance is level & upright. Service call if repeated.
Check gas supply is turned on, turn the heater OFF and then
ON again. If the heater fails to ignite after 4 attempts a
Service call will be required.
As above.
Service call.
Clean filters. If error continues a service call will be required.
L
o
w
r e
o r
o
m
e t
m
p
o t
b
e
o l
w
Service call.
Service call.
Service call.
Service call.
Service call.
S
e
v r
c i
e
c
a
. l l
Service call.
S
e
v r
c i
e
c
a
. l l
Service call.
Press the ON/OFF button
call if repeated.
17
Possible Remedy
, n
w
h
e
n
p
o
w
r e
e r
s
o t
e r
, d
p
a
n
t i
o i
n
p
o r
c
e
d
u
e r
p
a
g
e
. 9
a
r i
l i f
e t
s r
(
W
e
e
k
y l
. )
a
r i
l i f
e t
s r
(
W
e
e
k
y l
. )
s
u
p
p
ly on at the meter or cylinder.
r e
b
y
u
s
n i
g
h t
e
o
v
e
r r
d i
e
p
a
e t
d
R
e
m
e
d
y