Mark Herlihy
January 26, 2025
Unit working on LO & Med but will only work for a couple minutes on high. Then shuts it self down.
1 comments:
Mr. Anderson
February 10, 2025
The Rinnai REH-20DT could be shutting down after a few minutes of running on high due to several possible reasons:
1. Oxygen Depletion Sensor (ODS) Activation – If the heater is in a poorly ventilated area, the ODS may detect low oxygen levels and shut the unit off for safety. 2. Gas Supply Issue – If the gas pressure is insufficient or does not match the rating plate requirements (LP or NG), the heater may not function properly. 3. Blocked or Dirty Components – A clogged burner or pilot assembly can cause improper combustion, leading to shutdown. 4. Overheating Protection – If the heater is located too close to combustible materials or restricted airflow, it may overheat and shut down as a safety measure. 5. Faulty Thermostat or Controls – If the thermostat control (on T-Models) malfunctions, it might cause the heater to cycle off incorrectly.
Checking ventilation, gas supply, and cleaning the heater may help resolve the issue. If the problem persists, professional inspection is recommended.
Super high-efficency (se+) series infrared gas heater (40 pages)
Summary of Contents for Rinnai REH-20DT
Page 3
USAGE AND INSTALLATION MUSTS READ THESE RULES AND THE INSTRUCTIONS CAREFULLY. CHECK FAILURE TO FOLLOW THESE COULD CAUSE A MALFUNCTION OF THE HEATER RESULTING IN DEATH, SERIOUS BODILY INJURY AND/OR PROP- ERTY DAMAGE. THIS HEATER IS DESIGNED FOR USE ONLY WITH ONE TYPE OF GAS, EITHER L.P.G.
Page 4
CHILDREN ADULTS SHOULD TO THE HAZARD OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE HEATER. CONTAINERS MUST INDOORS. DO NOT INSTALL IN A WINDY AREA. SUCH AS FACING A WINDOW OR A DOOR LEADING TO THE OUTSIDE.
Need help?
Do you have a question about the REH-20DT and is the answer not in the manual?
Questions and answers
Unit working on LO & Med but will only work for a couple minutes on high. Then shuts it self down.
The Rinnai REH-20DT could be shutting down after a few minutes of running on high due to several possible reasons:
1. Oxygen Depletion Sensor (ODS) Activation – If the heater is in a poorly ventilated area, the ODS may detect low oxygen levels and shut the unit off for safety.
2. Gas Supply Issue – If the gas pressure is insufficient or does not match the rating plate requirements (LP or NG), the heater may not function properly.
3. Blocked or Dirty Components – A clogged burner or pilot assembly can cause improper combustion, leading to shutdown.
4. Overheating Protection – If the heater is located too close to combustible materials or restricted airflow, it may overheat and shut down as a safety measure.
5. Faulty Thermostat or Controls – If the thermostat control (on T-Models) malfunctions, it might cause the heater to cycle off incorrectly.
Checking ventilation, gas supply, and cleaning the heater may help resolve the issue. If the problem persists, professional inspection is recommended.
This answer is automatically generated