CONTROLS REFERENCE GUIDE
Illusion, Mirage, Vision, Espirit
(120VAC/240VAC Convertible pack)
Initial Start-up
When your spa is first actuated, it will go into priming mode, indicated by "Pr." The Priming mode
will last for less than 5 minutes and then the spa will begin to heat the spa and maintain the water temperature in the
Standard mode.
Temperature Adjustment can only function between 80°F - 104°F / 26°C - 40°C
The start-up temperature is set at 100°F (37°C). The last measured temperature is constantly displayed on the LCD.
Note: the last measured spa temperature displayed is current only when the pump has been running for at least 2
minutes.
To display the set temperature, press firmly on the Temp Up or Down pad once. Each time either pad is pressed again, the set
temperature will increase or decrease depending on which pad is pressed. After three seconds, the LCD will automatically display the
last measured spa temperature
Jets
Firmly press the "Jets" button once to activate the low speed of the pump and again for the high speed. Firmly press the "Jets"
button again to turn off the pump. If left running, the low speed of the pump will automatically turn off after 4 hours, and the
high speed will automatically turn off after 15 minutes. The low speed of the pump may also activate for at least 2 minutes
every 30 minutes to detect the spa temperature and then to heat to the set temperature if needed, depending upon mode. When
the low speed turns on automatically, it cannot be deactivated from the panel; however, the high speed may be started.
Light
Firmly press the "Light" button to turn the light on and off. If left on, the light automatically turns off after 4 hours.
Operational Mode:
The default operational mode is preset from the factory for Standard Mode. In order to be programmed into either alternative
Economy or Sleep modes as described below dip switch #7 on the power supply board must be moved downward into the "off"
position as described on Page 9.
Mode
Mode is changed by pressing the Temp Up orDown button, then pressing the 'light" button.
Standard Mode
is programmed to maintain the desired temperature. Note the last measured spa temperature displayed is
current only when the pump has been running for at least 2 minutes.
"St"
will be displayed momentarily when you switch into Standard mode.
Economy Mode
heats the spa to the set temperature only during filter cycles.
"Ec"
will display solid when temperature is not current, and will alternate with temperature when temperature is current.
Sleep Mode
heats the spa to within 20º F (6.6º C) of the set temperature only during filter cycles.
"SL"
will display solid when temperature is not current, and will alternate with temperature when temperature is current
10