18 Battery Connector Problems

Fault Symptoms
Customer:
Mobile does not switch on
Exchange
Battery
Connector
Connector BATTERY
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding components!
Resolder new component afterwards.
E-commerce order number:
E-commerce order name:
Soldering temperature:
IRIS Diagnose Code:
Technical Documentation
TD_Repair_L1-L3_AX72_R1.1.pdf
Battery connector
Problems
Watch for oxidation and
damaged pads of the
Connector
not
Check the status of the
okay
Connector visually
not
okay
Use the resistor test
function of a
multimeter to check
connection between
spring contacts and
soldering contacts.
The value must be
~0Ω
L36334-Z97-C213
CONNECTOR BATTERY 3-POL
~ 360°C Tip Temp.
13000 Battery/Mechanical Damage
Company Confidential
GRT:
Current measured failed
okay
okay
2006©BenQ
Release 1.1
Back to customer
without repair
caused by customer
SCRAP
- has to be send
separately to WSC
- check for twisted or
bent contacts
- check for dry joints
Continue with
higher repair level
Page 40 of 41