Standing Pilot Ignition System Wiring - Heatilator ND3630M, ND3933M,ND4236M Owner's Manual

Direct vent gas appliance
Table of Contents

Advertisement

Optional
SPST Wall Switch
Optional Remote
RED
GRN*
* GRN wire only for
use with optional
wall switch
WSK-MLT
Figure 10.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram
D. Standing Pilot Ignition System Wiring
This standing pilot ignition system wiring does not require
a 110 VAC supply to operate. A wiring diagram is shown
in Figure 10.3.
It is recommended that a 110 VAC junction box be installed
for use with a fan or remote control. (See Figure 10.4 for
junction box wiring.)
CAUTION
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Pilot
Ignitor
Thermocouple
Copper
Tubing
ORG
Push
Button
Ignitor
Gas Inlet
Figure 10.3 Standing Pilot Ignition Wiring Diagram
Battery
or
Pack
+
-
WHT
Junction
+
-
3V
Adapter
BLK
WHT
RED
RED
Wall Switch (or
Thermopile
thermostat if
heater-listed)
RED
TAN
TO
PILOT
RED
TH
WHT
TP
TH/TP
BRN
To Burner
Manifold Pressure
Pilot
Adjustment Fitting
Adjustment
Manifold
Cap
(outlet)
Inlet Tap
Pressure Tap
Heatilator • Novus Mesh DV • 4031-552 Rev I • 11/07
Ignitor
Control
Box
To
ORG
Box
BLK
BRN
ORG
GRN
Valve
Note: Do not wire 110V to the millivolt valve (standing pilot)!
This will damage the valve.
WHT
GRN*
* GRN wire only
for use with
optional wall switch
WSK-MLT-HTL
Flame
Sensor
Pilot Assembly
WHT
WARNING
Shock Risk
Replace damaged wire with type 105° C
rated wire.
Wire must have high temperature
insulation.
Optional Accessories Requirements
Wiring for optional accessories should
be done now to avoid reconstruction.
41