Phase Conversion - A.O. Smith DRE 52 Instructions Manual

Commercial electric water heaters conversion kit
Hide thumbs Also See for DRE 52:
Table of Contents

Advertisement

Available languages

Available languages

IMMERSION THERMOSTAT MODEL TRANSFORMER
CONNECTION TABLES
Volts
208
Common & 208
240
Common & 240
277
Common & 277
480
Common & 480
V. PHASE CONVERSION
A. IMMERSION THERMOSTAT MODEL
THREE PHASE TO SINGLE PHASE
1. Disconnect blue wires and yellow wires from terminal L-3.
2. Connect all blue wires to terminal L-1 (with black wires).
3. Connect all yellow wires to terminal L-2 (with red wires).
4. Incoming power will be connected to
terminals L-1 and L-2 at job site.
B. IMMERSION THERMOSTAT MODEL
SINGLE PHASE TO THREE PHASE
1.
Disconnect blue wires from terminal L-1.
2.
Disconnect yellow wires from terminal L-2.
3.
Connect all blue wires and yellow wires to terminal L-3.
4.
Incoming power will be connected to terminals
L-1, L-2 and L-3 at job site.
Line On
Load on
Secondary
120V
IMMERSION THERMOSTAT MODEL TRANSFORMER
IMMERSION THERMOSTAT MODEL
SINGLE PHASE TERMINAL BLOCK
IMMERSION THERMOSTAT MODEL
THREE PHASE TERMINAL BLOCK
5