FIELD-INSTALLED ACCESSORY
DESCRIPTION AND USAGE
Roof Curbs (Vertical) - Full-perimeter galvanized steel sup-
port frame in 14- and 24-in. high designs provides wood nailer
to attach roof counter flashing. Insulated basepans in curb are
provided to prevent condensation. Ductwork attaches to rails
provided in the roof curb. A gasket is provided to form an air-
and watertight seal between unit and curb. The gasket meets
the standards of the NRCA (National Roofing Contractors'
Association).
SUGGESTED USE:
• Rooftop application for vertical discharge.
• Slab-mounted applications when elevation of the unit is
necessary.
Horizontal Adapters - The adapters are prefabricated, easily
field-assembled, and permit full perimeter mounting. Adapters
can be installed at the jobsite before unit is installed, eliminating
a major leak source.
SUGGESTED USE:
• Rooftop application for horizontal discharge.
• Rooftop applications for horizontal discharge on units where
high air delivery cfms are required.
Two-Position Damper - Package consists of a low-leak
damper assembly. The damper will allow either 0 or 25% out-
door air into the unit any time the evaporator fan is running.
When the evaporator fan is off, the damper will be closed.
SUGGESTED USE:
• Allows a fixed percentage of outdoor air any time the evapo-
rator fan is on, but closes when the evaporator fan is off to
prevent cold backdrafts and wasted energy.
• The damper may be used on either vertical or horizontal air-
flow applications.
Thermostats and Subbases - Provide staged cooling and
heating, automatic (or manual) changeover, fan control, and in-
dicator light.
SUGGESTED USE:
• To control unit operations.
Barometric Relief Package - This package is useful when it
is necessary to remove excess pressure from the conditioned
space.
NOTE: Optional economizer is required with this accessory.
Power Exhaust - This package is useful when it is necessary
to remove excess pressure from the conditioned space.
NOTE: Optional economizer is required with this accessory.
SUGGESTED USE:
• When the job requires the ability to relieve internal building
pressure and pressure losses through the return-air ductwork
are greater than 0.20 in. wg.
• When the job requires the ability to move large quantities
of air to relieve pressure in the conditioned space.
Head Pressure Control - Kit consists of an outdoor-air ther-
mostat that permits adequate head pressure control during
cooling operation at low outdoor-ambient temperatures. Refer
to Trade Prices for more details.
SUGGESTED USE:
• When cooling at low-ambient outdoor temperatures is
desired.
Time Guard Device - Package consists of a control to be
field wired into the unit controls, and provides a 5-minute delay
in compressor operation between cooling cycles.
SUGGESTED USE:
• Prevents compressor short cycling when rapid compressor
cycles may be a problem.
Electric Heat Packages - Each package consists of one or
more heater modules. Each module slides into keyed mounting
slots in the fan discharge section.
SUGGESTED USE:
• To provide heat in the unit when required.
Economizer - See description listed under Factory-Installed
Options Description and Usage section on page 1.
Remote Control Panel - The remote control panel accessory
for field use.
SUGGESTED USE:
Emergency Heat Package - The emergency heat package in-
SUGGESTED USE:
Model Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Air Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2
Page