Ground Resistance (Autorange) Specifications
Range
0.025 to 0.250
0.250 to 1.000
1.001 to 9.999
10.00 to 50.00
50.01 to 99.99
100.0 to 200.0
200.1 to 400.0
400.0 to 600.0
600.1 to 1500
Accuracy Note: Loop resistance non‐inductive, external field < 50A/m, external electrical field
<1 V/m, conductor centered
Ground / Leakage Current Specifications
Range
0.300 to 1.000mA
1.00 to 10.00mA
10.0 to 100.0mA
100 to 1000mA
0.20 to 4.00A
4.00 to 30.00A
Notes: 50/60Hz bandwidth, True RMS sensing, Crest Factor < 3.0
High and Low Alarm (programmable)
High Alarm
Low Alarm
All rights reserved including the right of reproduction in whole or in part in any form
Resolution
0.002
0.02
0.02
0.04
0.04
0.4
2
5
20
Accuracy (% of reading)
± (2.0% ± 0.05mA)
± (2.0% ± 0.03mA)
± (2.0% ± 0.3mA)
± (2.0% ± 0.3mA)
± (2.0% ± 0.03A)
± (3.0% ± 0.03A)
Range
0‐1510
0‐1510
Copyright © 2013 FLIR Systems, Inc.
ISO‐9001 Certified
www.extech.com
Accuracy (of reading)
± (1.5% + 0.05
± (1.5% + 0.05
± (1.5% + 0.1
± (2.0% + 0.3
± (2.0% + 0.5
± (3.0% + 1.0
± (5.0% + 5
± (10% + 10
± 20%