13

Operating Instructions

A. Before Lighting Appliance
Before lighting this appliance determine if it has a Standing
Pilot or Intellifi re ignition system by opening the control
access panel to view wiring system and gas valve. If this
appliance has a red or black ignitor button (see Figure
10.1) this appliance has a Standing Pilot ignition system.
If there is no red or black ignitor button, this appliance has
an Intellifi re ignition system.
CAUTION
If installing Intellifi re ignition battery backup:
• Do not install batteries if the backup mode may not be
used for extended time.
• Batteries may leak.
• Install batteries only when needed for power outage.
Before operating this appliance have a qualifi ed
technician:
• Remove all shipping materials from inside and/or
underneath the fi rebox.
• Review proper placement of logs, rockwool, lava
rock, and vermiculite.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper
position.
• Ensure that the fl ow of combustion and ventilation air
is not obstructed (front grilles and vent caps).
WARNING
Glass door must be in place when
appliance is operating. Risk of:
Combustion Fumes
Fire
Do NOT operate appliance with glass door removed.
• Open viewing glass for servicing only.
• Glass door MUST be in place and sealed before
operating appliance.
• Only use glass door certifi ed for use with appliance.
• Glass replacement should be done by qualifi ed
technician.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
Heat & Glo • 6000GBV, 6000GBV-IPI • 2104-900 Rev. G • 9/08
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. Do
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to the owner's information manual provided with this ap-
pliance. For assistance or additional information consult a
qualifi ed installer, service agency or the gas supplier.
B. Check Appliance Draft
Check draft of appliance
to verify proper venting
conditions.
• Close all windows and
doors, turn on all exhaust
fans in home.
• Appliance is to be com-
pletely assembled to nor-
mal operating condition.
• Turn on appliance and
allow to operate for at
least 10 minutes.
• Check draft as shown in
Figure 13.1. This can be
done using a smoke or
fl ame producing match.
• Hold lit match at bot-
tom edge of draft hood
opening and observe
flame/smoke per the
fi gure.
D R A F T H O O D
F L A M E U P
- A C C E P TA B L E -
F L A M E IN
- G O O D -
F L A M E O U T
- B A D -
Figure 13.1