Battery Performance On Unit With Run Down Program - HTC Prodigy Service Manual

Pda phone product
Table of Contents

Advertisement

8.4
Battery Performance on unit with Run Down Program ( not confirm yet)
-> Copy Run Down software "power
detect" and "model.txt" to unit (My
Document) or SD card
-> Make sure turn off all RF function
( BT/WLAN/GSM) setting already before
executing Run down test.
-> Execute power detect
-> There is no necessary to adjust setting of
power management, the program will
stop automatically after one hour and
detecting status per 2 minutes.
-> After one hour later the program will stop,
open the log file of PowerCap.txt. Please
check battery remaining capacity.
HTC confidential
© 2001, HTC Corporation. All rights reserved.
TOTAL 84
CONT.ON. 47 PAGE NO. 46