Wideshot qsr system
wide angle hd point of view camera system with a 82.2 horizontal
field of view manual lens and the quick-connect sr interface (20 pages)
Image: Basic Wiring Configuration ........................11 IR SHOT Commander Remote Control ........................12 Image: Vaddio IR SHOT Commander Hand-held IR remote ................12 Compliance and CE Declaration of Conformity - WideSHOT ................. 13 Warranty Information ............................... 14 ...
Do not operate any device if it has been dropped or damaged. In this case, a Vaddio technician must examine the product before operating. To reduce the risk of electric shock, do not immerse in water or other liquids and avoid extremely humid conditions.
5) Logo: Really Cool Logo Badge (RCLB). The RCLB is affixed to the base in a recessed ovoid area. 6) The Aluminum Base and Steel Cylindrical Body: Please don’t drop it on your foot, it’s fairly substantial. WideSHOT WallVIEW SR System Document Number 342-0695 Rev A Page 5 of 20...
Manual Focus Control (Outermost ring) Adjust Near Lens Positions from Factory IRIS - Full Open Zoom - Full Wide Focus - user to set WideSHOT WallVIEW SR System Document Number 342-0695 Rev A Page 6 of 20...
For IP or USB 2.0 Streaming, use 1080p/50 1080p/29.97 position “0” (720p/59.94) for best results 480p/59.94 1080p/25 Set the rotary switch to an unassigned position and a medium grey privacy mask is displayed. WideSHOT WallVIEW SR System Document Number 342-0695 Rev A Page 7 of 20...
EZ-POWER VIDEO and RS-232 ports on the back of the WideSHOT camera to the Quick-Connect SR Interface. The EZ-POWER VIDEO jack on the camera is highlighted as a reminder that there is 24 VDC power on that Cat-5 cable. WideSHOT WallVIEW SR System Document Number 342-0695 Rev A Page 8 of 20...
To dress the cabling, push the extra cable back into the wall opening. Step 5: Connect the Vaddio 24 VDC, 2.0 Amp power supply to a power outlet and to the Quick Connect SR Interface. Power will travel down the Power/Video Cat. 5 cable to the camera. The camera will boot up and in a few seconds, HSDS (differential) video will travel back down the Cat-5 cable and be ready to accept control information from the IR remote control or other camera controller.
(Simulated HD Video Feed) Serial Control for Color Presets, Scenes and configuration (if required) Most camera settings can be set with the IR SHOT Commander using the OSD. WideSHOT WallVIEW SR System Document Number 342-0695 Rev A Page 11 of 20...
ZoomSHOT and WideSHOT Camera Systems (shipped with these products) Vaddio ClearVIEW HD-18, HD-19, HD-20, PowerVIEW HD-22, HD-30 and REVEAL™ HD-18 (limited functionality) The Vaddio IR Shot Commander is also compatible with the Sony® EVI series and the BRC series PTZ cameras. Basic Instructions: ...
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference including interference that may cause undesired operation of the device. Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the user’s authority to operate this equipment.
Vaddio Customer Service: Vaddio will test, repair, or replace the product or products without charge if the unit is under warranty. If the product is out of warranty, Vaddio will test then repair the product or products. The cost of parts and labor charge will be estimated by a technician and confirmed by the customer prior to repair.
0.45 lbs. ( 0.20411657 kg) Weight Rack Mount Adapter: 998-6000-002 - Holds three (3) Quick-Connect SR Interfaces Accessory Planet in Front Page Header: Venus (filtered for detail) WideSHOT WallVIEW SR System Document Number 342-0695 Rev A Page 15 of 20...
TXD (to RXD of control source) 2: P SR I PPENDIX OUTS FOR UICK ONNECT NTERFACE Table: DE-15 - YPbPr Pin-Out YPbPr Pr GND Y GND Pb GND WideSHOT WallVIEW SR System Document Number 342-0695 Rev A Page 16 of 20...
TXD (to RXD of control source) NOTE: The Vaddio WideSHOT Control Protocol is similar, but not identical to the Sony® VISCA™ command set in order to be compatible with several popular control devices. Not all VISCA commands are supported and there are many WideSHOT specific commands in the following Command and Inquiry Lists.
The Camera module does not support an Auto Exposure option. The Auto selection will reset Contrast, Saturation, Brightness, and shutter speed to defaults. Auto Exposure inquiry will return Auto if Contrast, Saturation, Brightness, and shutter are at defaults. Manual if not. WideSHOT WallVIEW SR System Document Number 342-0695 Rev A Page 18 of 20...
Don’t use 25/30 unless necessary DEFAULT (Sets to Defaults) Enter RESET (Restarts Camera) Enter VERSION (Software Version) 201X-XXXX Firmware build info RETURN Return to Main Menu Exit Exists OSD Mode EXIT WideSHOT WallVIEW SR System Document Number 342-0695 Rev A Page 19 of 20...
Need help?
Do you have a question about the WIDESHOT WALLVIEW SR and is the answer not in the manual?
Questions and answers