3.2. Cooling only type
Indoor unit ... 220V 50Hz Single phase
Outdoor unit ... 220V 50Hz Single phase / 380V 50Hz 3phase
Indoor unit
Service Ref.
Outdoor unit
Mode
Capacity (W)
Total Input (kW) (In + Out)
Input (kW)
Current (A)
Current (A)
Starting current (A)
Indoor unit ... 230V 50Hz Single phase
Outdoor unit ... 230V 50Hz Single phase / 400V 50Hz 3phase
Indoor unit
Service Ref.
Outdoor unit
Mode
Capacity (W)
Total Input (kW) (In + Out)
Input (kW)
Current (A)
Current (A)
Starting current (A)
Indoor unit ... 240V 50Hz Single phase
Outdoor unit ... 240V 50Hz Single phase / 415V 50Hz 3phase
Indoor unit
Service Ref.
Outdoor unit
Mode
Capacity (W)
Total Input (kW) (In + Out)
Input (kW)
Current (A)
Current (A)
Starting current (A)
PKA-P2.5FAL
PKA-P3FAL
PKA-P2.5FAL
PKA-P3FAL
1
PU-P2.5VGA
PU-P3VGA
PU-P2.5VGA
1
Cool
Cool
6,400
7,800
2.67
3.41
0.09
0.09
0.43
0.43
11.96
15.55
70
84
PKA-P2.5FAL
PKA-P3FAL
PKA-P2.5FAL
PKA-P3FAL
1
PU-P2.5VGA
PU-P3VGA
PU-P2.5VGA
1
Cool
Cool
6,450
7,850
2.70
3.42
0.09
0.09
0.43
0.43
11.82
15.08
74
89
PKA-P2.5FAL
PKA-P3FAL
PKA-P2.5FAL
PKA-P3FAL
1
PU-P2.5VGA
PU-P3VGA
PU-P2.5VGA
1
Cool
Cool
6,500
7,900
2.72
3.43
0.09
0.09
0.43
0.43
11.78
14.64
77
93
PKA-P4FAL
PKA-P4FAL
1
PU-P3YGA
PU-P4YGA
Cool
Cool
7,800
9,500
3.41
3.44
0.09
0.11
0.43
0.52
5.54
5.55
38
41
PKA-P4FAL
PKA-P4FAL
1
PU-P3YGA
PU-P4YGA
Cool
Cool
7,850
9,600
3.42
3.46
0.09
0.11
0.43
0.52
5.46
5.48
40
43
PKA-P4FAL
PKA-P4FAL
1
PU-P3YGA
PU-P4YGA
Cool
Cool
7,900
9,700
3.43
3.47
0.09
0.11
0.43
0.52
5.46
5.49
41
45
34
1
1
1