Mitsubishi Electric Mr.Slim PKH-P3FALH Technical & Service Manual page 11

Pkh/pka series wall mounted split-type,heat pump air conditioners, split-type, air conditioners, r407c
Hide thumbs Also See for Mr.Slim PKH-P3FALH:
Table of Contents

Advertisement

Item
Function
Capacity
Total input
Service Ref.
Power supply(phase, cycle,voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow(Low-High)
External static pressure
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Unit drain pipe O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
Running current
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
Between the indoor &
outdoor unit
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor
: D.B. 27˚C(80˚F), W.B. 19˚C (66˚F)
Refrigerant piping length (one way) : 5m (16ft)
2. Guaranteed operating range
Upper limit
Cooling
Lower limit
3. Above data based on indicated voltage
Indoor Unit
Single phase 240V 50Hz
Outdoor Unit Single phase 240V 50Hz / 3 phase 415V 50Hz
Service Ref.
Btu/h
W
kW
kW
A
A
kW
K/min(CFM)
Pa(mmAq)
kW
dB
mm(in.)
mm(in.)
W
D
mm(in.)
mm(in.)
H
kg(lbs)
A
A
kW
Internal thermostat, HP switch, Discharge thermo. / Thermal relay, Discharge thermo, HP switch, Anti-phase protector.
W
kW
K/min(CFM)
dB
Cooling
W
mm(in.)
mm(in.)
D
H
mm(in.)
kg(lbs)
kg(lbs)
L
Liquid
mm(in.)
Gas
mm(in.)
Indoor side
Outdoor side
Height difference
Piping length
Indoor
D.B. 35˚C, W.B. 22.5˚C
D.B. 46˚C
D.B. 19˚C, W.B. 15˚C
D.B. -5˚C
PKA-P3FAL / PKA-P3FAL
PKA-P3FAL / PKA-P3FAL
Single phase, 50Hz, 220-230-240V
Munsell 3.4Y 7.7/0.8
Line flow (direct) x 2
Wireless remote controller & built-in
PU-P3VGA / PU-P3YGA
Single phase, 50Hz, 220-230-240V / 3 phase, 50Hz, 380-400-415V(4wires)
Linear Expansion Valve
NE52VNJM / NE52YDJM
Propeller (direct) x 1
Outdoor
: D.B. 35˚C(95˚F), W.B. 24˚C (75˚F)
Outdoor
11
1
Cooling
27,000
7,900
3.43
1
0.09
0.43
0.80
Plate fin coil
0.040
15-20 (530-706)
0(direct blow)
39-45
20(13/16)
1,400(13/16)
235(9-1/4)
340(13-3/8)
24(53)
14.64/5.46
93/41
Munsell 5Y 7/1
Hermetic
2.5
Line start
38
Plate fin coil
0.070
50(1,770)
49
900(35-7/16)
330+20(13+3/4)
855 (33-5/8)
82(181)
R407C
3.7(8.2)
1.6 (Ester)MEL56
9.52 (3/8)
15.88 (5/8)
Flared
Flared
Max. 50m
Max. 50m