Mitsubishi Electric Mr.Slim PKH-P3FALH Technical & Service Manual page 10

Pkh/pka series wall mounted split-type,heat pump air conditioners, split-type, air conditioners, r407c
Hide thumbs Also See for Mr.Slim PKH-P3FALH:
Table of Contents

Advertisement

2. Cooling only type
Item
Function
Capacity
Total input
Service Ref.
Power supply(phase, cycle,voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow(Low-High)
External static pressure
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Unit drain pipe O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
Running current
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
Between the indoor &
outdoor unit
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor
: D.B. 27˚C(80˚F), W.B. 19˚C (66˚F)
Refrigerant piping length (one way) : 5m (16ft)
2. Guaranteed operating range
Upper limit
Cooling
Lower limit
3. Above data based on indicated voltage
Indoor Unit
Single phase 240V 50Hz
Outdoor Unit Single phase 240V 50Hz
Service Ref.
Btu/h
W
kW
kW
A
A
kW
K/min(CFM)
Pa(mmAq)
kW
dB
mm(in.)
mm(in.)
W
mm(in.)
D
mm(in.)
H
kg(lbs)
A
A
kW
W
kW
K/min(CFM)
Cooling
dB
mm(in.)
W
mm(in.)
D
H
mm(in.)
kg(lbs)
kg(lbs)
L
Liquid
mm(in.)
Gas
mm(in.)
Indoor side
Outdoor side
Height difference
Piping length
Indoor
D.B. 35˚C, W.B. 22.5˚C
D.B. 46˚C
D.B. 19˚C, W.B. 15˚C
D.B. -5˚C
PKA-P2.5FAL / PKA-P2.5FAL
PKA-P2.5FAL / PKA-P2.5FAL
Single phase, 50Hz, 220-230-240V
Munsell 3.4Y 7.7/0.8
Line flow (direct) x 2
Wireless remote controller & built-in
PU-P2.5VGA / PU-P2.5VGA
Single phase, 50Hz, 220-230-240V
Linear Expansion Valve
Internal thermostat, HP switch, Discharge thermo.
Propeller (direct) x 1
Outdoor
: D.B. 35˚C(95˚F), W.B. 24˚C (75˚F)
Outdoor
10
1
Cooling
22,200
6,500
2.72
1
0.09
0.43
0.80
Plate fin coil
0.040
15-20 (530-706)
0(direct blow)
39-45
20(13/16)
1,400(13/16)
235(9-1/4)
340(13-3/8)
24(53)
1
11.78
77
Munsell 5Y 7/1
Hermetic
NE41VMJM
1.9
Line start
38
Plate fin coil
0.070
50(1,770)
48
900(35-7/16)
330+20(13+3/4)
855 (33-5/8)
82(181)
R407C
3.3(7.3)
1.2 (Ester)MEL56
9.52 (3/8)
15.88 (5/8)
Flared
Flared
Max. 50m
Max. 50m