Specifications
Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions (Height) x (Width) x (Depth)
Weight
Water Holding Capacity
Connection Sizes
Power Supply
Materials
Safety Devices
Accessories
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
28
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water pressure,
water supply, piping conditions, and water temperature.
Specifications
Installation
Air Supply/Exhaust
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Performance
NG
LP
45°F (25°C) Rise
°F Mode:
°C Mode:
°F Mode:
°C Mode:
Specification
NR83-DVC
Indoor Wall Mounted
Power Vented
Direct Ignition
15-150 psi
0.5 GPM (2 L/min.)
23.6" (600mm) x 13.8" (350mm) x 9.4" (240mm)
49 lbs.
0.2 Gallon (0.95L)
3/4"
3/4"
3/4"
120 VAC (60Hz)
NG : 82W
LP : 90W
Freeze Prevention 161W
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Lightning Protection
Device (ZNR), Overheat Prevention Device, Freezing
Prevention Device, Fan Rotation Detector
Anchoring Screws
Maximum Performance
180,000 btuh
180,000 btuh
6.7 GPM (25.4 L/min.)
0.5-8.3 GPM (2-31.4 L/min.)
100-140°F (In 5°F intervals) (9 Options)
37-48°C (In 1°C intervals),
50,55,60°C (In 5°C intervals) (15 Options)
120,130,140°F (Original is 120°F)
50,55,60°C (Original is 50°C)
Minimum Performance
18,000 btuh
18,000 btuh

Hide quick links: