Noritz proTOUGH NR83DVC Installation Manual

Noritz proTOUGH NR83DVC Installation Manual

Tankless gas water heater
Hide thumbs Also See for proTOUGH NR83DVC:

Advertisement

Quick Links

Installation Manual
TANKLESS GAS WATER HEATER
NR83DVC (GQ-2457WS-FFA US)
Potential dangers from accidents during installation and use are divided into the following three
categories. Closely observe these warnings, they are critical to your safety.
DANGER
WARNING
CAUTION
WARNING:
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Prohibited
Requests to Installers
• In order to use the water heater safely, read this installation manual carefully, and follow the in-
stallation instructions.
• Failures and damage caused by erroneous work or work not as instructed in this manual are not
covered by the warranty.
• Check that the installation was done properly in accordance with this Installation Manual upon
completion.
• After completing installation, either place this Installation Manual in a plastic pouch and attach it to
the side of the Water Heater (or the inside of the pipe cover or recess box if applicable), or hand it
to the customer to retain for future reference.
SBB80JW-3
Rev. 11/20
DANGER indicates an imminently hazardous situation which,
if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
Disconnect
Power
CAUTION
Low NOx
Approved by
SCAQMD
14 ng/J or 20 ppm
(Natural Gas Only)
(Indoor Installation)
Ground
FOR USE IN RESIDENTIAL OR MANUFACTURED HOME APPLICATIONS.
Installation must conform with local codes, or in the absence of
local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54-
latest edition and/or the Natural Gas and Propane Installation
Code CSA B149.1 - latest edition.
When applicable, installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part
3280 or the Canadian Standard CAN/CSA-Z240 MH Mobile
Homes, Series M86.
Noritz America reserves the right to discontinue, or change at any
time, the designs and/or specifications of its products without notice.
NORITZ AMERICA
CORPORATION
Be sure to do
*SBB80JW*

Advertisement

Table of Contents
loading

Summary of Contents for Noritz proTOUGH NR83DVC

  • Page 1 Home Construction and Safety Standard, Title 24 CFR, Part 3280 or the Canadian Standard CAN/CSA-Z240 MH Mobile Homes, Series M86. Noritz America reserves the right to discontinue, or change at any time, the designs and/or specifications of its products without notice. SBB80JW-3 Rev.
  • Page 2: Included Accessories

    Included Accessories The following accessories are included with the unit. Check for any missing items before starting installation. Part Shape Q’ty Part Shape Q’ty Owner's Guide, Warranty, Anchoring Screw Installation Manual each (this document) The accessories listed below are not Optional Accessories included with the units, but may be necessary for installation.
  • Page 3: Quick Connect Multi System Installation

    Quick Connect Multi System Installation • The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord. The Quick Connect Cord is 6' (2m) long. Install the units 2-18" (50-450mm) apart from each other to ensure the cord will be able to reach between the units.
  • Page 4: Before Installation

    WARNING Precautions on Vent Pipe • This appliance requires the use of special concentric type vent pipe specified by Noritz America. Do not attempt to use materials that are not specified for use on this appliance. Improper venting may result in a fire, property damage, or exposure to Carbon Monoxide.
  • Page 5: Choosing Installation Site

    Choosing Installation Site * Locate the appliance in an area where leakage from the unit or connections will not result in damage to the area adjacent to the appliance or to the lower floors of the structure. When such installation locations cannot be avoided, a suitable drain pan, adequately drained, must be installed under the appliance.
  • Page 6 Contact local utilities for code requirements in your area or call: 1-866-766-7489 and re- quest instructions. The Commonwealth of Massachusetts: The water heater can be used for hot water only and not in a combination of domestic and space heating. For Venting Manufacturers Requirements, see websites listed below: Noritz N-Vent www.noritz.com...
  • Page 7: Installation Clearances

    Installation Clearances WARNING Before installing, check for the following: Install in accordance with relevant building and mechanical codes, as well as any local, state or national regulations, or in the absence of local and state codes, to the National Fuel Gas Code ANSI Z223.1/NFPA 54 –...
  • Page 8 Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with the Natural Gas and Propane Installation Code CSA B149.1. Vent Terminal Air Supply Inlet Area Where Terminal...
  • Page 9 Installation Securing to the wall • The weight of the device will be applied to the wall. If the strength of the wall is not sufficient, reinforcement must be done to prevent the transfer of vibration. • Do not drop or apply unnecessary force to the device when installing. Internal parts may be damaged and may become highly dangerous.
  • Page 10: Vent Pipe Installation

    The venting system shall be installed in accordance with the water heater manufacturer's instructions and, if applicable, the venting system manufacturer's instructions. This appliance requires the use of special concentric type vent pipe specified by Noritz America. Do not attempt to use materials that are not specified for use on this appliance.
  • Page 11 Maximum Vent Length Adjustment Dipswitches The unit can be adjusted to accommodate longer vent runs; refer to the below table to find the maximum vent length based on the number of elbows. Adjust the dip switches according to the vent condition noted in the tables below.
  • Page 12 • Make the vertical pipe as short as possible. • Noritz Concentric vent pipe is approved for use on • Do not common vent or connect more than this appliance with zero clearance to combustibles.
  • Page 13 Vertical Vent Termination 3' (0.9m) or more • Terminate at least 6' (1.8m) from the combus- tion air intake of any appliance, and 3' (0.9m) Rain Cap from any other building opening, gas utility me- ter, service regulator etc. • Enclose exterior vent systems below the roof Air Intake Pipe line to limit condensation and protect against...
  • Page 14: Gas Piping

    The installer must be professionally trained to do such work and must always follow all local and national codes and regulations. Gas line sizing calculations must be performed for every installation. Please contact Noritz America at 866-766-7489 if you have any questions or concerns.
  • Page 15 Refer to the NFPA 54 for details. Please contact Noritz for details. For corrugated stainless steel tubing (CSST) capacity tables, please consult with the manufacturer.
  • Page 16 BTU/Cubic Foot ratings. For simplification of your calculations, 1 Cubic Foot of Gas is approximately equivalent to 1000 BTU. Sample Gas Line Instructions 1. Size each outlet branch starting from the furthest Noritz Tankless Gas Water Heater using the Btuh required and the length from the meter. Barbecue (180,000 Btuh) 2.
  • Page 17 Table 3. Maximum Undiluted Propane (LP) Delivery Capacity in Thousands of BtuH (0.5” WC Pressure Drop) [Schedule 40 Metallic Pipe] Length (including fittings) Pipe 100' 125' 150' 175' 200' Size (3m) (6m) (9m) (12m) (15m) (18m) (24m) (30m) (38m) (45m) (53m) (60m) 1/2"...
  • Page 18: Water Piping

    Installation and service must be performed by a qualified plumber. In the Water Piping Commonwealth of Massachusetts, this product must be installed by a licensed plumber or gas fitter in accordance with the Massachusetts Plumbing and Fuel Gas Code 248 CMR Sections 2.00 and 5.00. Observe all applicable codes. This appliance is suitable for potable water and space heating applications.
  • Page 19 • In order for the freeze prevention heaters to operate, the water heater must have power at all times. Damage to the water heater as a result Total Hardness* : 200 mg/L (12 gpg) or less of the below is not covered by the Noritz Aluminum : 0.05 to 0.2 mg/L or less America Limited Warranty.
  • Page 20: Water Treatment System

    = 1, 2, 3, 4, F # = 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 Damage to the water heater as a result of the items below is not covered by the Noritz America Limited Warranty. • Water in excess of 12 gpg (200mg/L) of hardness •...
  • Page 21 Procedure for Flushing the Heat Exchanger This procedure is only intended for use by a qualified service professional or authorized Noritz Service Representative. Any unauthorized use of this procedure may result in voiding the warranty.Please contact Noritz America (866-766-7489) for additional support.
  • Page 22 Flushing the Heat Exchanger (For Single Unit) 1. Open the Front Cover. 2. Connect theblue connector***** marked "FLUSH" near the Circuit Board. Water Heater Circuit Board Connect ***** The connector color is blue and labeled “FLUSH”. Manifold Plate FLUSH 3. Then the code “CCC” is displayed on the 4.
  • Page 23 1. Connect the blue connector marked "FLUSH" for unit needing to be flushed. (The water heater is isolated from Quick Connect Multi system when the “blue connector for flushing” is connected. Not need to disconnect the Connect Cord.) Sub Water Heater Main Water Heater Connect Circuit Board...
  • Page 24: Plumbing Applications

    Combination Potable Water and Space Heating System If the Air Handler does not control the water flow automatically, the Scale detection feature will not work. Notes: 1. Noritz recommends the use of an Isolation Kit with the installation. These kits include an integrated shut-off and service valve with unions and a pressure relief valve.
  • Page 25: Electrical Wiring

    Electrical Wiring Consult a qualified electrician for the electrical work. Do not connect electrical power to the unit until all electrical wiring has been completed. Disconnect Power This appliance must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
  • Page 26 Changing Other Features Adjusting the Temperature Display Note: The setting must be done within the first 10 minutes of connecting electrical power to the water heater. Table of Setting Items Item No. Item Choices (factory defaults shaded) Celsius / Liter °F / gal °C / L Fahrenheit / Gallon...
  • Page 27: Operation Panel

    Operation Panel * The water heater has been factory set to allow a maximum temperature setting of 120 °F (50 °C). To access higher temperature settings through the remote controller, follow the below steps. <When setting the maximum temperature to 130-140 °F (55-60 °C)> 1.
  • Page 28: Pump Wiring

    * This feature is not available when using the Quick Pump Wiring Connect Multi System feature. Connecting the pump control wire 1. Leave enough slack so that the pump control wires will stay connected if the unit is removed from the Pump Control wall.
  • Page 29 For Quick Connect Multi System Installation Connecting Quick Connect Cord-2 use part #QC-2 only. (sold separately). Caution The wire coloring on the Quick Connect Cord-2 will not be the same as the wire coloring of the connection plug inside the unit. 1.Red 1.Red 1.White...
  • Page 30: Maintenance

    Maintenance Periodically check the following to ensure proper operation of the water heater. • The venting system must be examined periodically by a qualified service technician to check for any leaks or corrosion. Yellow Flame or • The burner flame must be checked periodically Lifting Flame for a proper blue color and consistency.
  • Page 31: Lighting Instructions

    * If both units do not ignite, switch which unit will ignite first by pressing the Max. or Min. Mani-fold Pressure Set Button on the circuit board. (*2) Press Max. or Min. Manifold Unit A Ignites Unit A Doesn't Ignite Pressure Set Button on Unit B Unit B Doesn't Ignite Unit B Ignites...
  • Page 32 Dimensions <inch(mm)> 13.2" (336mm) 9.4" (240mm) 0.4" - 1.8" (10 - 45mm) 6 - 0.2" x 0.4" (6 x10mm) OBLONG HOLE 4.8" (121mm) 1.1" (28mm) 13.8" (350mm) 5.5" (140mm) 13.1" (334mm) 3.9" (100mm) FLUE COLLAR Ø5.0" (Ø128mm) 2.8"(70mm) Ø3.1" (Ø80mm) AIR INLET 1.4"...

This manual is also suitable for:

Gq-2457ws-ffa us