PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure
34, page 23).
2. Open propane/LP supply tank valve for
propane/LP fireplace or main gas valve
located on or near gas meter for natural
gas fireplace.
3. Make sure control knob of fireplace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas valve (see Figure 35 or
Figure 36, page 23). Apply noncorrosive
leak detection fluid to all joints. Bubbles
forming show a leak. Correct all leaks at
once.
5. Light fireplace (see Operation, page 27).
Check all other internal joints for leaks.
6. Turn off fireplace (see To Turn Off Gas to
Appliance, page 28).
INSTALLING OPTIONAL WALL
MOUNT SWITCH - GWMS2
1. Connect one terminal of 25 ft. wire for
wall switch to TPTH terminal on valve.
Connect remaining wire terminal to TH
terminal on valve. Make sure that wire ter-
minals are in positions on unit as pictured
in Figure 37. If wires are not connected as
shown switch will not work.
2. Route 25 ft. wire through openings pro-
vided on sides of burner system to a con-
venient location to mount your switch.
3. Connect one bare wire end to each termi-
nal of the GWMS2 wall switch.
4. Install wall switch and cover into wall.
Figure 37 - Connecting Wall Switch to
Control Valve
24
FIREPLACE INSTALLATION
Continued
To Wall
Switch
Accessory
www.desatech.com
INSTALLING OPTIONAL WIRELESS
HAND-HELD REMOTE CONTROL
HRC100 AND HRC200 SERIES
NOTICE: Use only alkaline bat-
teries (not included).
Installing Remote Receiver
1. Open bottom louver and locate switch
bracket on the right.
2. Unscrew switch bracket. Lean bracket
forward so you are able to access back
of remote receiver.
3. Locate battery clip mounted on back of
receiver. Slide a 9-volt alkaline battery (not
included) through clip (see Figure 38).
4. Attach terminal wires to battery.
5. Connect wires from receiver to TH and
TPTH to control valve (see Figure 39).
6. Replace switch bracket.
Receiver
9-Volt
Alkaline
Battery
Figure 38 - Attaching Alkaline Battery to
Receiver
To Optional
Remote
To Wall
Thermostat
Accessory
Figure 39 - Control Valve Terminals
Terminal
Wires
Battery Clip
116192-01M