45° Elbow
Venting with Two 90° Elbows
Vertical (V
Note: Vertical (V
) + Vertical (V
1
Figure 23 - Vertical Venting
Configuration Using Two 90° Elbows
(Vertical Round High Wind Termination
Shown)
HIGH ALTITUDE INSTALLATION
Your DESA Heating, LLC direct-vent fireplace
has been tested and approved for elevations
from 0-2000 feet (USA) and elevations from
0-4500 feet (Canada).
Fireplaces for High Altitude (models ending
in -HA) are for installation above 4000 feet
only. These fireplaces are equipped with parts
specific for higher altitudes.
When installing a non-high altitude fireplace
at an elevation above 2000 feet (in the USA),
you may need to decrease the input rating
by changing the existing burner orifice to
116192-01M
VENTING INSTALLATION
Note: Install
restrictor into inner
collar of fireplace
as shown.
) Horizontal (H)
1
5' min.
6' max.
6' min.
12' max.
7' min.
18' max.
8' min.
20' max.
) = 40' max.
2
www.desatech.com
Continued
45° Elbow
Figure 24 - Vertical Venting Configuration
With No Horizontal Run (Vertical Round
High Wind Termination Shown)
a smaller size. Reduce input 4% for each
1000 feet above sea level. Check with your
local gas company for proper orifice size
identification.
When installing this fireplace at an elevation
above 4500 feet (in Canada), check with local
authorities.
IMPORTANT: For horizontal installations
above 2,000 feet, it is recommended that a
12" extension pipe be added before starter
elbow (see Figure 25, page 18) and a round
horizontal termination be used.
Vertical Venting
V = 40' max.
Note: Install
restrictor into inner
collar of fireplace
as shown.
17