Step 4. Configuring Client-Plc Communication; Step4. Configuring Client-Plc Communication - Omron WE70-AP Operation Manual

Fa wireless lan unit
Table of Contents

Advertisement

[For Reference]
To check access to an access point, specify LAN-end IP address (such as 192.168.0.1) of the access
point based on a procedure Connection Check, Opening Setup Screen (P.2-13).
• A setup screen of the access point is displayed.
* If access is controlled by a password, a password input is requested.

Step 4. Configuring Client-PLC Communication

Configure a terminal MAC address. A MAC address of PLC Ethernet unit must be set to a client CL-1.
<To Configure>
1.
Click
2.
Click
4.
Click
3.
Enter
Example. The Ethernet unit CJ1W-ETN21 has a label of Ethernet address (MAC address) on its right side.
(1) Select "settings" menu, "Basic settings".
* A "Basic settings" screen is displayed.
(2) Enter a MAC address of PLC Ethernet unit in the [Communicating unit's
MAC address]. (Example:00-00-0A-68-70-4A)
(3) Click <Apply and restart>.
CJ1W-ETN21
ETHERNET UNIT
Lot No.
OMRON Corporation
MADE IN JAPAN
Ethernet Address
MAC address (12 digits)
Chapter 4. Advanced Setup
4-13