Chapter 2. Installation & Connection
● To Mount on a DIN Rail
Do not install a product with a pencil-type antenna in a metal panel as it may result in degradation of radio
performance.To install this product in a panel, use and install a magnetic-base antenna outside the
panel.See "Options" of "Appendices", "Antenna" (P.Appendix-3).
Applicable Rail
There are 2 types of rails with a width
of 35mm, height of 7.5mm or 15mm.
(Conformance to DIN, EN, IEC, and
JIS C2812 standards)
2
Mounting DIN Rail Adapter
Insert a spring
A
Hold the part A and insert the tip
Pull it to the right and lower it while pressing the spring.
<Mounting>
<Demounting>
2-6
WT30-FT001
WT30-FT002
Mount it on the main unit and
clamp it using screws (M3).
Mounting screws for this wireless
unit must be tightened with torque
of 4.4 to 5.3in. lb. (0.5 to 0.6N.m)
Hitch a tab on the top to the DIN rail
DIN Rail
Pull the bottom side forwards
WE70-AP
FA WIRELESS LAN ACCESS POINT
POWER
MODE
LAN
WIRELESS
Insert a flat-head screw driver
under the lower tab and pull downward
Model
Rail
TH35-7.5
TH35-15
DIN rail length (unit mm)
Part A
TH35-7.5 Details
of part A
7.5
1 ± 0.04
Unhitch a tab from the DIN rail
DIN Rail
Pull the lower part
Specification
Rail width 35mm and height 7.5mm
Rail width 35mm and height 15mm
Less than 0.3
TH35-7.5 Details
of part A
15
1 ± 0.04
0
-0.4
15