Installation Manual
Canada
TANKLESS GAS WATER HEATER
Potential dangers from accidents during installation and use are divided into the following three
categories. Closely observe these warnings, they are critical to your safety.
DANGER
WARNING
CAUTION
WARNING:
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Prohibited
Requests to Installers
• In order to use the water heater safely, read this installation manual carefully, and follow the
installation instructions.
• Failures and damage caused by erroneous work or work not as instructed in this manual are not
covered by the warranty.
• Check that the installation was done properly in accordance with this Installation Manual upon
completion.
• After completing installation, please either place this Installation Manual in a plastic pouch and
attach it to the side of the water heater (or the inside of the pipe cover or recess box if applicable),
or hand it to the customer to retain for future reference. Also, be sure to fill in all of the required
items on the warranty and to hand the warranty to the customer along with the Owner's Guide.
CERTIFIED
R
KS-09-0008
Rev. 10/09
NR98-SV
(Indoor/Outdoor Installation)
NR98-OD
(Outdoor Installation)
DANGER indicates an imminently hazardous situation which,
if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
Disconnect
Power
CAUTION
FOR USE IN RESIDENTIAL, COMMERCIAL, OR MANUFACTURED
HOME APPLICATIONS. (NR98-OD only)
Installation must conform with local codes, or in the absence of local codes,
the National Fuel Gas Code, ANSI Z223.1/NFPA 54- latest edition and/or CSA
B149.1, Natural Gas and Propane Installation Code (NSCNGPIC).
When applicable, installation must conform with the Manufactured Home Con-
struction and Safety Standard, Title 24 CFR, Part 3280 or the Canadian Standard
CAN/CSA-Z240 MH Mobile Homes, Series M86. (NR98-OD only)
Noritz America reserves the right to discontinue, or change at any
time, the designs and/or specifications of its products without notice.
Ground
NORITZ AMERICA
CORPORATION
Be sure to do

Advertisement

Table of Contents
loading

Summary of Contents for Noritz NR98-SV

  • Page 1 Installation Manual NORITZ AMERICA CORPORATION Canada TANKLESS GAS WATER HEATER NR98-SV (Indoor/Outdoor Installation) NR98-OD (Outdoor Installation) Potential dangers from accidents during installation and use are divided into the following three categories. Closely observe these warnings, they are critical to your safety.
  • Page 2: Included Accessories

    Cord (8m(26')) Isolation Valves Pipe Cover (includes pressure (PC-2S) relief valve) [Outdoor installation only] Remote Controller Outdoor Junction Box [ NR98-OD only ] [ NR98-SV only ] Part Shape Part Shape Q’ty Q’ty Outdoor Vent Cap (VC4(-1)) Recess Box (RB-700)
  • Page 3: Quick Connect Multi System Installation

    Quick Connect Multi System Installation • The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord. The Quick Connect Cord is 2m (6'). long. Install the units 50 - 450mm (2-18") apart from each other to ensure the cord will be able to reach between the units.
  • Page 4: Before Installation

    Checkup • Check the fixing brackets and vent pipe yearly for damage or wear. Replace if necessary. WARNING Check the Gas Ex. For Natural Gas NR98-SV • Check that the rating plate indicates the correct type of gas. NR98-SV 199,900 BTU •...
  • Page 5: Choosing Installation Site

    (e.g., hair spray or spray detergent) are used. Ignition failures and malfunction may occur as a result. Prohibited [For NR98-SV only] • Carbon Monoxide Poisoning Hazard. Do not install this water heater in a mobile home, recreation vehicle or on a boat.
  • Page 6 Be sure to do steam from entering in the equipment. [For NR98-SV only] • Make sure that the location allows installation of the exhaust vent as specified. • For outdoor installation, use the outdoor vent cap.
  • Page 7: Installation Clearances

    Install in accordance with relevant building and mechanical codes, as well as any local, state or national regulations, or in the absence of local and state codes, to the National Fuel Gas Code ANSI Z223.1/NFPA 54 – latest edition. In Canada, see NSCNGPIC for detailed requirements. [ For NR98-SV ] Item Check Illustration •...
  • Page 8 [ For NR98 -OD] Item Check • Maintain the following clearance from both combustible 600mm (24") and non-combustible materials. (300mm (12")) * ( ) indicates the distance when installing a heat insulat- or more ing board (incombustible material other than metal, with thickness of 2.5mm (0.1") or more) or "section of build- ing effectively finished with incombustible material."...
  • Page 9 Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. Vent Terminal Area Where Terminal is Not Permitted Air Supply Inlet Indoor Installation Outdoor Installation...
  • Page 10 Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. [ For NR98-SV] Maintain the following clearances to any Illustration opening in any building: •...
  • Page 11 [ For NR98- OD] Maintain the following clearances to any Illustration opening in any building: • 0.3m (1') below, 0.3m (1') horizontally from, or 0.3m (1') above any door, operable window, or gravity air inlet into any building. 0.9m (3') above any forced air inlet within 3m (10').
  • Page 12: Installation

    Installation Securing to the wall • The weight of the device will be applied to the wall. If the strength of the wall is not suffi- cient, reinforcement must be done to prevent the transfer of vibration. • Do not drop or apply unnecessary force to the device when installing. Internal parts may be damaged and may become highly dangerous.
  • Page 13: Vent Pipe Installation

    Vent Pipe Installation (Indoor Installation Only) [ For NR98-SV] WARNING CARBON MONOXIDE POISONING Follow all vent system requirements in accordance with relevant local or state regulation, or, in the absence of local or state code, in the U.S. to the National Fuel Gas Code ANSI Be sure to do Z233.1/NFPA 54 –...
  • Page 14: Vertical Vent Termination

    Horizontal Vent Termination • Terminate at least 300mm (12") above grade or above snow line. • Terminate at least 2.1m (7') above a public Hanger walkway, 1.8m (6') from the combustion air Straps Elbow intake of any appliance, and 0.9m (3') from any other building opening, gas utility meter, Wall Termination...
  • Page 15: Combustion Air

    Supply combustion air to the units as per the National Fuel Gas Code, ANSI Z223.1 and Combustion Air in Canada, in accordance with NSCNGPIC. • Provide two permanent openings to allow circulation of combustion air. 250mm (10") • Make each opening 199 square inches if they provide indoor air, and 100 square inches for 500mm (20") outdoor air.
  • Page 16: Gas Piping

    Gas Piping Follow the instructions from the gas supplier. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ⁄ psi (3.5 kPa). The Appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ⁄...
  • Page 17 Gas Line Sizing for a Noritz Gas Water Heater Adapted from UPC 1997 Maximum Natur Natural Gas Delivery Capacity in Cubic Feet per Hour (0.60 Specific Gravity, 0.5" WC Pressure Drop) Length in Feet Pipe Size 3m (10') 6m (20') 9m (30') 12m (40') 15m (50')
  • Page 18: Water Piping

    Installation and service must be performed by a qualified plumber. In the Water Piping Commonwealth of Massachusetts, this product must be installed by a licensed plumber or gas fitter in accordance with the Massachusetts Plumbing and Fuel Gas Code 248 CMR Sections 2.00 and 5.00. Observe all applicable codes. This appliance is suitable for potable water and space heating applications.
  • Page 19 Supply water piping Hot water piping • Do not use PVC, iron, or any piping which has been • Do not use lead, PVC, iron or any piping which treated with chromates, boiler seal or other chemicals. has been treated with chromates, boiler seal or •...
  • Page 20: Water Treatment

    Water Treatment If this water heater will be installed in an application where the supply water is hard, the water must be treated with either a water softener, which removes the hardness, or by using sequestering agents, such as the Noritz Scale Shield, that reduce the amount of scale deposits. Refer to the below tables for sug- gested treatment and maintenance measures to be taken based on the water hardness level.
  • Page 21: Plumbing Applications

    Plumbing Applications Recirculation System Notes: 1. Size the pump to provide a maximum of 7.5 L/min. (2 GPM) through the system at 3m (10 ft) of head plus piping losses. Hot Water Return Adjust the flow using a globe valve and verify the NORITZ Cold Water Supply flow rate with the maintenance monitors.
  • Page 22: Electrical Wiring

    Consult a qualified electrician Electrical Wiring for the electrical work. Do not connect electrical power to the unit until all electrical wiring has been completed. Disconnect Power This appliance must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
  • Page 23: Remote Controller

    To keep the water heater off, let the unit sit for 30 sec. to return to the original display. • The NR98-SV, OD can be programmed so that it will default to one of four temperatures if the remote controller is removed (80°C, 60°C, 55°C, 50°C (176°F, 140°F, 130°F, 122°F)). To change the default temperature, connect the temperature selection wire as shown in the above diagram.
  • Page 24: Connecting Remote Controller Cord To Unit

    Connecting Remote Controller Cord to Unit • Keep the remote controller cord away from the freeze prevention heaters in the unit. • Tie the redundant cord outside the water heater. Do not put the extra length inside the equipment. • The remote controller cord can be extended up to 90m (300') with 18AWG wire. •...
  • Page 25: Pump Wiring

    * This feature is not available when using the Quick Con- Pump Wiring nect Multi System feature. Connecting the pump control wire 1. Leave enough slack so that the pump control wires will stay connected if the unit is removed from the Pump Control wall.
  • Page 26: Connecting Quick Connect Cord

    For Quick Connect Multi System Installation Connecting Quick Connect Cord use a Quick Connect Cord (sold separately). Caution The wire coloring on the Quick Connect Cord will not be the same as the wire coloring of the connection plug inside the unit. 1.Red 1.Red 1.White...
  • Page 27: Maintenance

    Periodically check the following to ensure proper Maintenance operation of the water heater. • The venting system must be examined periodically by a qualified service technician to check for any leaks or corrosion. • The burner flame must be checked periodically for a proper blue color and consistency. •...
  • Page 28: Lighting Instructions

    CAUTION Handling after trial operation • If the unit will not be used immediately, close off all gas and water shutoff valves, drain all of the water out of the unit and the plumbing system to prevent the unit and system from freezing, and bleed the gas out of the gas line.
  • Page 29 Dimensions NR98-SV < mm [inch] > 336mm [13.2"] HEIGHT OF EACH FITTINGS FROM BOTTOM OF CASE NR98-SV 4- 13mm [ 0.5"] 2-6.5 x 13mm [0.3 x 0.5"] 45mm [1.8"] HOT WATER OUTLET 240mm [9.4"] OBLONG HOLE 10mm [0.4"] 55mm [2.2"] 95mm [3.7"]...
  • Page 30 Remote Controller RC-7650M carefully before carrying out installation. Installation Guide NORITZ AMERICA CORPORATION Note Do not connect power to the water heater before the remote controller has been properly installed. Recommended installation location of the remote controller is in a bathroom.
  • Page 31 Installation 1. Apply Wall Packing to the rear side of the 3. Remove the cover of the remote control, remote controller. mark the location of the screw holes, and drill holes for the wall anchors. 2. Connect the remote controller wires to the 4.
  • Page 32: Installing The Remote Controller Outdoor Junction Box

    [For outdoor installation only] Installing the Remote Controller Outdoor Junction Box 5. Slide the box nut over the remote controller 1. Insert the remote controller wires through the wires and screw it onto the wall pipe. wall pipe and secure the wall pipe to the remote controller.
  • Page 33: Manuel D'installation

    Manuel d’installation NORITZ AMERICA CORPORATION Canada CHAUFFE-EAU À GAZ SANS CUVE NR98-SV (Installation intérieure/extérieure) NR98-OD (Installation extérieure) Les dangers potentiels provenant d’accidents pendant l’installation et l’utilisation sont classés dans les trois catégories suivantes. Observez bien ces avertissements, ils sont indispensables à votre sécurité.
  • Page 34: Accessoires Inclus

    8m (26') Clapets d’isolement Couvre-tuyau (comprenant une soupape de (PC-2S) sûreté de la pression) Boîte de dérivation extérieure de la télécommande [ NR98-OD uniquement ] [ NR98-SV uniquement ] Pièce Forme Qté Pièce Forme Qté Bouchon d’évent extérieur (VC4(-1)) Boîtier encastr...
  • Page 35: Schéma Du Système

    Installation du multisystème par raccordement rapide • Le multisystème à raccordement rapide permet d’installer deux unités ensemble en utilisant uniquement le cordon à raccordement rapide. Le cordon de raccordement rapide mesure 2m (6') de long. Installez les deux unités entre 50mm - 450mm (2-18") d’écart chacune pour garantir que le cordon puisse relier les deux unités.
  • Page 36: Avant L'installation

    • Vérifiez les dégâts ou usures des appliques de fixation et du tuyau d’évent chaque année. Remplacez-les au besoin. AVERTISSEMENT Vérifiez le gaz Ex. Pour le gaz naturel NR98-SV • Vérifiez que la plaque signalétique indique le NR98-SV 199,900 BTU 199,900 BTU type de gaz correct.
  • Page 37 Des défaillances ou dysfonctionnement de l’allumage pourraient en résulter. Interdit [ Pour NR98-SV uniquement ] • Risque d’empoisonnement au monoxyde de carbone N’installez pas le chauffe-eau dans un mobile home, une caravane ou sur un bateau. [ Pour NR98-OD uniquement ] [ Installation extérieure ]...
  • Page 38 [ Pour NR98-SV uniquement ] • Assurez-vous que l’emplacement permet l’installation de la conduite d’évacuation comme spécifié. • Pour l’installation extérieure, utilisez le bouchon d’évent extérieur. S’il est nécessaire de ventiler au-dessus du niveau du toit dans une installation extérieure, utilisez un scellant à...
  • Page 39: Dégagement Pour L'installation

    à la norme ANSI Z223.1/NFPA 54 - dernière édition du National Fuel Gas Code. Au Canada, voir NSCNGPIC pour le détail des exigences. [ Pour NR98-SV ] Rubrique Vérification Illustration •...
  • Page 40 [ Pour NR98-OD ] Rubrique Vérification Illustration • Maintenez le dégagement suivant des matériels com- bustibles et non-combustibles. Au moins * ( ) indique la distance lors de l'installation d'une plaque 600mm (300mm) de calorifugeage (matière incombustible autre que le 24"...
  • Page 41 Exigences de dégagement des bouches de l’évent par rapport aux ouvertures du bâtiment * Toutes les exigences de dégagement sont conformes à la norme ANSI Z21.10.3 et le National Fuel Gas Code, ANSI Z223.1 et au Canada NSCNGPIC. Bouche de l’évent Zone où...
  • Page 42 Exigences de dégagement des bouches de l’évent par rapport aux ouvertures du bâtiment * Toutes les exigences de dégagement sont conformes à la norme ANSI Z21.10.3 et le National Fuel Gas Code, ANSI Z223.1 et au Canada NSCNGPIC. [ Pour NR98-SV ] Maintenez les dégagements suivants par Illustration rapport aux ouvertures d’un bâtiment :...
  • Page 43 [ Pour NR98-OD ] Maintenez les dégagements suivants par Illustration rapport aux ouvertures d’un bâtiment : • 0.3m (1') dessous, 0.3m (1') horizontalement à partir de, ou 0.3m (1') au dessus d'une porte, fenêtre utilisable ou entrée d'air dans un bâtiment. 0.9m (3') au-dessus d’une entrée d’air forcée dans la limite de 3m (10').
  • Page 44: Fixation Au Mur

    Installation Fixation au mur • Le poids de l’appareil sera appliqué sur le mur. Si la force du mur n’est pas suffisante, un renforcement doit être fait pour empêcher un transfert de la vibration. • Ne laissez pas tomber ni n’usez de force inutile sur l’appareil lors de l’installation. Les pièces internes pourraient être endommagées et devenir très dangereuses.
  • Page 45 (Installation extérieure Installation du tuyau d’évent uniquement) [ Pour NR98-SV ] AVERTISSEMENT EMPOISONNEMENT AU MONOXYDE DE CARBONE Respectez toutes les exigences du système de ventilation conformément aux réglementations locales ou de l'état ou en l'absence de réglementation locale ou de l'état, Veillez à...
  • Page 46 • Terminez au moins 300mm (12") au-dessus du Bouche de l’évent horizontal sol ou du niveau de la neige. • Terminez au moins 2.1m (7') au-dessus d’un trottoir, Courroies 1.8m (6') de l’entrée d’air comburant d’un appareil et 0.9m (3') d’une ouverture d’un bâtiment, compteur à suspension Coude gaz, régulateur de gaz, etc.
  • Page 47: Air Comburant

    Alimentez en air comburant les unités selon la norme ANSI Z223.1 du National Fuel Gas Air comburant Code et au Canada selon le NSCNGPIC. • Prévoyez deux ouvertures permanentes permettant la circulation de l’air comburant. 250mm (10") • Chaque ouverture doit être de 194 pouces carrés si elles fournissent l’air intérieur et 100 500mm pouces carrés pour l’air extérieur.
  • Page 48: Conduite De Gaz

    Conduite de gaz Suivez les instructions du fournisseur de gaz. L’appareil et son robinet d’arrêt du gaz doivent être débranchés du système de conduites de distribution du gaz durant tout essai de pression à des pressions supérieures à ⁄ psi (3,5 kPa). L’appareil doit être isolé...
  • Page 49 Calibrage de la canalisation de gaz pour un Noritz Chauffe-eau à gaz Adapté de UC1997 Capacité maximum de distribution du gaz naturel en pied cubique par heures (Gravité spécifique 0.60, Perte de pression 0.5" WC) Calibre Longueur en pieds 3m (10') 6m (20') 9m (30') 12m (40') 15m (50')
  • Page 50 L'installation et l'entretien doivent être assurés par un plombier qualifié. Dans l'état du Commonwealth of Massachusetts, cet appareil doit être Conduite d’eau installé par un plombier ou un monteur d'installation au gaz agréés conformément aux sections 2.00 et 5.00 du Massachusetts Plumbing and Fuel Gas Code 248 CMR.
  • Page 51 Conduite de distribution d’eau Conduite d’eau chaude • N'utilisez pas de PVC, acier ou de tuyaux traités au • N'utilisez pas de plomb, PVC, acier ou de tuyaux traités au chromate, scellement par plomb pour chaudière ou chromate, scellement par plomb pour chaudière ou autres autres produits chimiques.
  • Page 52 Traitement de l’eau Si le chauffe-eau est installé dans une application où l’eau est dure, celle-ci doit être traitée avec un adoucisseur, qui élimine la dureté ou en utilisant des agents séquestrant, comme la cartouche Noritz Scale Shield, qui diminue la quantité de dépôts calcaires. Reportez-vous aux tableaux ci-dessous pour le traitement suggéré...
  • Page 53 Plomberie Système de recirculation Remarques : 1. Calibrez la pompe pour fournir un maximum de 7.5 L/min (2 GPM) à travers le système à 3m 10 ft) de hauteur de refoulement plus les pertes de tuyauterie. Ajustez le débit à l’aide d’un robinet à soupape et Retour d’eau chaude Alimentation en vérifiez la vitesse d’écoulement avec les...
  • Page 54: Installation Électrique

    électrique est raccordement électrique fixe de l’appareil. détectée. ( Pour NR98-SV uniquement ) ATTENTION La décharge électrostatique peut avoir une incidence sur les composants électroniques. Prenez des mesures pour empêcher les décharges électrostatiques du personnel ou des outils à main pendant l'installation et l'entretien du...
  • Page 55 Pour laisser le chauffe-eau hors tension, laissez l'unité reposée pendant 30 secondes et revenir à l'affichage initial. • Le NR98-SV, OD peut être programmé de sorte qu'il revienne au réglage par défaut d'une des quatre températures si la télécommande est déplacée (80°C, 60°C, 55°C, 50°C (176°F, 140°F, 130°F, 122°F)).
  • Page 56: Cordon De Télécommande

    Raccordement du cordon de télécommande à l’unité • Eloignez le cordon de télécommande des chauffages en prévention du gel dans l’unité. • Attachez le cordon d’alimentation qui dépasse à l’extérieur du chauffe-eau. Ne placez pas de longueur superflue dans l’équipement. •...
  • Page 57 * Cette fonction n’est pas disponible lorsque vous utilisez la fonction Câblage de la pompe multisystème à raccordement rapide. Raccordement du câble de commande de la pompe 1. Laissez suffisamment de jeu de sorte que les câbles de commande de la pompe restent Etiquette du câble branchés si l’unité...
  • Page 58 Pour l’installation du multisystème par raccordement rapide, Branchement du cordon de raccordement rapide utilisez un cordon de raccordement rapide (vendu séparément). Attention La couleur des câbles sur le cordon de raccordement rapide sera différente de celle des câbles de la fiche de jonction dans l’unité. 1.Rouge 1.Rouge 1.Blanc...
  • Page 59: Test De Fonctionnement

    Vérifiez régulièrement les points suivants pour Maintenance garantir un bon fonctionnement du chauffe-eau. • Le système de ventilation doit être examiné régulièrement par un technicien de service qualifié pour vérifier les fuites ou la corrosion. • La flamme du brûleur doit être vérifiée régulièrement pour une couleur bleue et une consistance adéquates. •...
  • Page 60: Instructions D'allumage

    ATTENTION Manipulation après le test de fonctionnement • Si l’unité ne sera pas utilisée immédiatement, fermez tous les robinets d’arrêt du gaz et de l’eau, vidangez toute l’eau de l’unité et du système de plomberie pour prévenir le gel de l’unité et du système et purgez la canalisation de gaz.
  • Page 61 Dimensions NR98-SV < mm [inch] > 336mm [13.2"] Hauteur de chaque aller de bas du coffret NR98-SV 4- 13mm [ 0.5"] 2-6.5 x 13mm [0.3 x 0.5"] Trou oblong SORTIE D’EAU CHAUDE 45mm [1.8"] 240mm [9.4"] 10mm [0.4"] 55mm [2.2"] 95mm [3.7"]...
  • Page 62: Guide D'installation

    Télécommande RC-7650M d’installation avant de procéder à l’installation. Guide d’installation NORITZ AMERICA CORPORATION Remarque Ne branchez pas l’alimentation au chauffe-eau avant que la télécommande ne soit correctement installée. Il est recommandé d'installer la télécommande dans la salle de bain. Liste des pièces incluses Câble de raccordement...
  • Page 63 Installation 3. Retirez le couvercle de la télécommande, 1. Appliquez la garniture du mur derrière la marquez l’emplacement des trous de vis et télécommande. 2. Raccordez les câbles de la télécommande au percez les trous pour les ancrages pour mur. cordon de télécommande distinct.
  • Page 64 Installation de la boîte de dérivation extérieure de la télécommande 5. Faites glisser l’écrou de la boîte par-dessus 1. Insérez les câbles de la télécommande à les câbles de la télécommande et vissez-le travers le tuyau du mur et fixez-le à la dans le tuyau du mur.