Installation Location
Choose the placement of the thermostats early in the construction process to
enable proper wiring during rough-in.
Consider the following:
•
Interior Wall.
•
Keep dry. Avoid potential leakage onto the control.
•
Relative Humidity max 92% up to 40°C, 50% RH above 40°C. Non-condensing
environment.
•
No exposure to extreme temperatures beyond 2-50°C.
•
No draft, direct sun, or other cause for inaccurate temperature readings.
•
Away from equipment, appliances, or other sources of electrical interference.
•
Easy access for wiring, viewing, and adjusting the display screen.
•
Approximately 1.5 m off the finished floor.
•
The maximum length of wire is 150 m.
•
Strip wire to 10 mm for all terminal connections.
•
Use standard 4 conductor, 0.75 or 1.0 mm
Removing The Thermostat Base
To remove the thermostat base:
•
Place a small slot screwdriver or similar
tool into the slot located on the top of
the thermostat.
•
While pushing down against the plastic
tab, pull the thermostat away from the
thermostat's base.
Mounting The Thermostat Base
If a single gang switch box is used,
an Adaptor Plate 008e is required to
mount the thermostat to the box.
•
Fasten the base of the
thermostat to the adaptor plate.
•
Feed the wiring through the
openings in the back of the
adaptor plate and thermostat.
•
Use the upper and lower screw
holes to fasten the adaptor plate
to the box.
-- - - - ---- - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- - - - --- ---- - - - - - - - - - - - - - - - - - - - - - - - - - -- -- - -- -- - - -