Download Print this page

Gatekeeper SKC-500DC Owner's Manual page 15

Sliding gate opener

Advertisement

adjusting can be achieved in two stages. Beginning with a 4cm adjustment. After the
4cm process has been tested if an additional 2cm is required a final micro adjustment
can be done. The maximum micro adjustment is 10cm. If you exceed this limit any
previous adjustment will be cancelled and micro adjustment will have to be re
programmed.
l
The open limit adjusting process also has three steps: rough, fine and micro adjusting.
The process is the same as the close limit adjusting as above.
Manual operation (see Fig.1)
If the gate has to be operated manually due to a power cut or malfunction of the automated
system, use the release key as follow:
l
Fit the supplied key in the hole.
l
Turn the key counter-clockwise to disengage the clutch.
l
Open and close the gate manually.
Safety Auto Reverse
Obstruction Sensor
The Obstruction Sensor continuously monitors the gate movement for any obstructions. If any
obstructions are detected when the gate is closing, the gate will stop and reverse back to the
open position. If any obstructions are detected when opening, the gate will stop. The factory
setting is set at MAXIMUM sensitivity. You may need to increase or decrease depending on
the weight and the condition of your gate.
Adjustment of the Auto-Reverse Function
? Tuning the auto -reverse safety function : To adjust the opening force, rotate the 'Open Force
VR2' knob (See control board scheme Figure 3 ) with a screwdriver. The resistance may be
increased or decreased by rotating clockwise or counterclockwise. To adjust the closing
force rotate the 'Close Force VR3' knob (See control board scheme Figure 3) with a

Advertisement

loading