Download Print this page

Gatekeeper SKC-500DC Owner's Manual page 12

Sliding gate opener

Advertisement

Press the same button again to s top the gate or the gate will stop at its closed position
automatically. After this setup is complete, then remember to make the first switch of SW
(DIP-switch) to OFF position (up) immediately. Thus 'the auto close function' has been
cancelled.
l
Set width / auto-close function of pedestrian mode: Pedestrian mode can be used to
open gate about 0.3~1.5 meters for people pass through.
? Set width of pedestrian mode : Make the first switch of SW (DIP-switch) to ON
position (down), press button 4 to open the gate (see Verify open direction section).
Wait until the gate travels the distance as your requirements (the distance range is
0.3m~1.5m or wait for 3~10 sec.), it is regarded as 'the width of pedestrian mode' . Then
press the same button to stop the gate, wait for some seconds (1~44 sec.). C lose the
gate by pressing the same button. Press the same button again to stop the gate or the
gate will stop at its closed position automatically. Then make the first switch of SW (DIP -
switch) to OFF position (up) immediately. Thus 'the width of pedestrian mode' has been
set.
If you open the gate with button 4, the gate will stop at the expected position that you
have set.
? Set auto-close function of pedestrian mode: Make the first switch of SW (DIP -
switch) to ON position (down), press button 4 to open the gate (see Verify open
direction section). Wait until the gate travels the distance as your requirements (about
3~ 10 sec.). Then press the same button to stop the gate, wait for some seconds as
your requirements (1~44 sec.), this period of time is regarded as 'auto-close time of
pedestrian mode' . Close the gate by pressing the same button. Press the same button
again to stop the gate or the gate will stop at its closed position automatically. Then
remember to make the first switch of SW (DIP-switch) to OFF position (up) immediately.
Thus 'the auto-close function of pedestrian mode' has been set. (Note: the new width of
pedestrian mode has been re-programmed and replaced the original width that you have
set in Set width of pedestrian mode section.) If you open the gate with button 4, the
gate will stop at the new expected position that you have set. After some seconds as
what you have set, the gate will close automatically.
l
Cancel width / auto-close function of pedestrian mode
? Cancel width and auto-close function of pedestrian mode (factory preset): Make
the first switch of SW (DIP-switch) to ON position (down), press button 4 to open the
gate (see Verify open direction section). Wait for more than 15 sec.. Then press the
same button to stop the gate, wait until the gate close automatically (45 sec). Stop the
gate by pressing the same button or the gate will stop at its closed position. Then make
the first switch of SW (DIP-switch) to OFF position (up) immediately. Thus 'the wid th and
auto-close function of pedestrian mode' have been cancelled.
? Cancel width of pedestrian mode, keep auto-close function of pedestrian mode:
Make the first switch of SW (DIP-switch) to ON position (down), press button 4 to open
the gate (see Verify open direction section). Wait for more than 15 sec.. Then press
the same button to stop the gate, wait several seconds as your requirements (1~44
sec.), then close the gate by pressing the same button, press the same button again to
stop the gate or the gate will stop at its closed position automatically. Then make the
firs t switch of SW (DIP -switch) to OFF position (up) immediately. Thus 'the width of
pedestrian mode' has been cancelled. 'The auto-close function of pedestrian mode' has
been reserved . (Note: the new auto -close time of pedestrian mode has been re-
programmed in the device and replaced the original auto-close time of pedestrian mode
which you have set in Set auto-close function of pedestrian mode section.)
? Keep width of pedestrian mode, cancel auto-close function of
pedestrian mode: Make the first switch of SW(DIP-switch) to ON position(down), press
button 4 to open the gate(see Verify open direction section). Wait until the gate travels
the distance as your requirements (the distance range is 0.3m~1.5m or wait for 3~10
sec.). Then press the same button to stop the gate, wait until the gate close
automatically (45 sec.). Stop the gate by pressing the same button or the gate will stop
at its closed position automatically. Then make the first switch of SW (DIP -switch) to
OFF position (up) immediately. Thus 'the width of pedestrian mode' has been reserved,
'the auto -close function o f pedestrian mode' has been cancelled. (Note: the new width of
pedestrian mode has been re-programmed in the device and replaced the original
width.)

Advertisement