Important Safety Measures 1) Please read this manual before installing the equipment. 2) Please follow all warning notices on the equipment and in the manual. 3) Please only use accessories which are recommended by your dealer or ones that are listed at the end of this manual. 4) Please protect cables well, especially near connection points.
4. Baud Rate Setting Baud Rates: 2400/S, 4800/s, 9600/s The #7 & #8 positions of switch S1 on the PCB are used for setting the baud rate. The default setting is 9600/S. This setting must match the setting in your DVR or controller device. Table for Baud Rate Setting Switch Positions Baud Rate...
7. Manually Limiting the Pan & Tilt Range The maximum angle of the pan/tilt mechanism is set at the factory (horizontal: maximum 356º, vertical: maximum 90º), it is unnecessary to adjust the limits of the mechanism unless there are special requirements of the installation. You can limit the pan range of your camera by adjusting the stop tabs (slices) on top of the mechanism.
9. Wiring for Dome System 100 feet of CAT5E twisted pair cable, and 20’ of power supply wiring is included with your dome camera. Additional CAT5E cable can be purchased from a variety of stores or distributors and easily spliced to your cable. Up to 1,000 feet of cable can be successfully used on an installation.
installation. Run wiring from the dome through the bracket, and attach the dome to the bracket exerting equal pressure on the three screws around the neck of the dome. Connect the house wiring from the control unit or DVR to the dome before mounting the dome if access to the dome wiring will be limited after mounting.