ATTENTION:
• It is necessary to check the heat pump operation parameters after the installation and before the first use.
• When the heat pump is running, the LED display shows the temperature of incoming water.
• If you switch off the heat pump using the On/Off button on the control LED display, thus putting the heat
pump into the STANDBY mode, the LED display will show the clock.
• The water temperature may be adjusted when the heat pump is running. Other parameters may only be
changed when the heat pump is in the STANDBY mode.
Parameter
Meaning
Setting the temperature of incoming water in
0
cooling mode
Setting the temperature of incoming water in
1
heating mode
2
Defrost cycle
3
Conditions for activating the defrosting function
4
Conditions for deactivating the defrosting function
5
Defrost termination time
Mode: 0 cooling, 1 heating and cooling, 2 heating
6
and cooling + auxiliary electric heating, 3 heating
7
Electronic expansion valve mode selection
8
Rapid mode for target heating
9
Rapid mode for target cooling
Intervals for manual adjustments of the electronic
A
expansion valve
B
Temperature of incoming water
C
Temperature of outgoing water
D
Capacitor temperature in the heating mode
E
Temperature of returned gas
F
Ambient temperature
G
Capacitor temperature in the cooling mode
H
Actual intervals of the electronic expansion valve
NOTES:
1.
If the heat pumps stops for 30 seconds, the filtration pumps shuts down automatically, if connected.
2. You can also control the filtration pump via the control LED display, provided that the filtration pump is
properly connected to the heat pump via the "PUMP" terminal.
3. In the event of using a 3-phase pump, a special 3-phase converter should be used.
Range
Factory setting
8−35°C
28°C
15−35°C
28°C
30−90 min
40 min
–30 to 0°C
–7°C
2 to 30°C
20°C
1 to 12 min
8 min
0−3
3 (heating)
0−1
1 (automatic)
–15 to 15°C
3°C
–15 to 15°C
10°C
18−94
70
–9 to 99°C
–9 to 99°C
–9 to 99°C
–9 to 99°C
–9 to 99°C
N*5
19
EN
Notes
Adjustable
Adjustable
Accurate value
setting
Accurate value
setting
Accurate value
setting
Accurate value
setting
Accurate value
setting
Accurate value
setting