Intrepid II, Model 1990CE
Nominal heat output ..............6. kW (1, 100 BTU/hr)
Minimum flue draught ......................1 Pa (0.048" WG)
Mean flue gas temp .............................. 337° C (639° F)
Efficiency (space heating) ...................................7.8%
Area heated ................... Up to 11 sq. m (100 sq. ft.)
Fuel size/type .................................410 mm (16") wood
Flue mass gas flow ............................................. 5.6 g/s
CO Emissions (@ 13% O
Loading ....................................................... Front or top
Chimney connector..................... 15 mm (6") diameter
Chimney flue size .......................15 mm (6") minimum
Flue exit position........................ Reversible, top or rear
Primary air ......Manual set, thermostatically maintained
Secondary air .........................................Self-regulating
Ash handling system ..................... Removable ash pan
Glass panels .........................High temperature ceramic
545 mm
(21 ")
610 mm
(24")
180 mm
(7 ")
Fig. 1 Intrepid II 1990CE dimensions.
30003840

Specifications

)............................ 900 ppm

510 mm (20")
540 mm (21 ")
545 mm (21 ")
3840
Intrepid EU
specifications
7/06
Weight ................................................ 101 kg (33 lbs.)
1
Width (leg-to-leg) .................................. 545 mm (1¹⁄₂")
Depth (leg-to-leg).................................. 350 mm (13³⁄₄")
Height to top of flue collar:
with regular legs .......................635 mm (5") top exit
1
............................................... 610 mm (4") rear exit
with optional short legs .............535 mm (1") top exit
............................................ 500 mm (19³⁄₄") rear exit
1. This value can vary depending on how the stove
is operated, the type and moisture content of the fuel
used, as well as the design, construction and climatic
location of your home. Figures shown are based on
nominal fuel consumption obtained under laboratory
conditions and on average efficiencies.
540 mm (21 ")
460 mm (18")
640 mm
(25 ")
Top exit
flue collar
height
350 mm (13 ")
Intrepid II Woodburning Stove
DRAWINGS NOT TO SCALE
31 mm
(1 ")
C L
520 mm
(20 ")