Download Print this page

Vermont Castings The Aspen II 1405CE Homeowner's Installation And Operating Manual page 20

Multi-fuel heater

Advertisement

Vermont Castings Aspen
gasket replacement
The Aspen uses rope-type fiberglass gaskets to make
a tight seal between some parts. With use, particularly
on those parts that move, gaskets can become brittle
and compressed and can begin to lose their effective-
ness. These will need periodic replacement.
The sizes of replaceable gasket are listed below, along
with their applications.
Gasket Diameter...
5/16" Round
3/8" Round
7/16" Round
1/2" Flat, two
1/2" Flat
Wait until the fire is out and the stove has cooled. Be
sure to follow the standard safety procedure for working
with dusty materials: Wear safety goggles and a dust
mask.
Step 1. Remove the existing gasket by grasping an
end and pulling firmly.
Step 2. Use a wire brush or a screwdriver to clean
the channel of any remaining cement or bits of gasket.
Remove stubborn deposits of cement with a cold chisel
if necessary.
fig. 25 Remove gasket then clean channel with wire brush.
ST559
Remove
Step 3. Determine the correct length of the appropri-
gasket
ate-sized gasket by laying it out in the channel. Allow an
11/30/00 djt
extra 1-2" (25-51 mm), and mark the spot to be cut.
Step 4. Remove the gasket from the channel, place it
on a wood cutting surface, and cut it at the marked spot
with a utility knife.
Twist the ends slightly to discourage the gasket from
unraveling.
Step 5. Lay an unbroken 1/8" (3 mm) bead of gasket
cement in the newly-cleaned channel.
Step 6. Starting at one end, press the gasket into the
channel.
Ensure a good joint where the gasket meets before
trimming any excess. Do not overlap the gasket ends or
leave ends with ragged edges.
Step 7. Press the gasketed part firmly against its
normal mating surface to seat the gasket evenly in its
20
II Multi-Fuel
®
...And the Parts it Seals
Flue Collar Gasket
Top
Door Gasket
Vertical Gasket for glass
Horizontal Gasket for glass
ST560
fig. 26 Lay a bead of gasket cement then press new gasket
in place.
channel. Close and latch the door to do this; close the
ST559
door on a piece of waxed paper to keep the cement
Remove
gasket
from migrating onto the non-gasketed part, or tap other
11/30/00 djt
parts
Step 8. Clean excess cement from around the channel.
Let the cement that holds the new gasket dry thor-
oughly.
adjust the door
The door latch may need adjustment as the gasket
material compresses over time. The latch engagement
may be tightened by removing the shim washers that
are under the Latch Plate. (Fig. 33) Remove only one
pair at a time. When a tight engagement can no longer
be achieved with no shim washers in place, the entire
door gasket should be replaced. Use only MHSC part
no. 700-0910.
the chimney System
creosote
Your Aspen is designed to reduce creosote buildup
significantly. However, regular chimney inspection and
maintenance must still be performed. For safety, good
stove performance, and to protect your chimney and
chimney connector, inspect your chimney and chimney
connector on a regular schedule. Clean the system if
necessary. Failure to keep the chimney and connector
system clean can result in a serious chimney fire.
when wood is burned slowly, it produces tar,
organic vapors and moisture that combine to form
creosote. the creosote vapors condense in the
relatively cool chimney flue. as a result, creosote
residue accumulates on the flue lining. when
ignited, this creosote makes an extremely hot fire
within the flue system that can damage the chimney
and overheat adjacent combustible material.
if you do have a chimney fire, promptly:
• close the damper and thermostat lever.
• get everyone out of the house.
• call the fire department.
You should inspect the system every two weeks during
the heating season as part of a regular maintenance
ST561
30003892

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Aspen ii 1405c