Page 1
Pantera Pool Pumps An earth leakage or residual current protection device must be fitted to all installations. Should you the installer or owner be unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor/manufacturer for the correct advice before proceeding...
Page 2
Relax - you’ve bought an Congratulations on your decision to purchase an Onga product. Onga is one of the best know brands in its field, with a proud local and international reputation. Onga is a brand for reliability, value for money and technological innovation.
Page 3
Continual Product Improvement We employ the best engineers both in Australia and around the world to develop new and better ways to take water further. Operational Excellence There is only one standard that we set ourselves for both product quality and the quality of our service. That standard is excellence...
PPP-1500-1P 11/2hp 1500W The Pantera range of pool pumps have been specifically designed to incorporate features that will provide reliable and efficient pump operation. The new technology wet end design integrates a unique moulded endshield cover and lip seal, protecting the motor from water damage making this range ideal for in-ground or above ground swimming pools.
Equipotential bonding terminal Drain plug Mounting holes The fittings on these pool pumps are constructed of ABS. Some PVC jointing compounds are incompatible with ABS possibly causing failure to the product. Check compound suitability prior to use. All glued fittings and pipe work should be allowed to dry to atmosphere for 24 hours before closing installation.
10) Do not connect pump to the mains water supply. The Pantera series of pool pumps is classified as "Double Insulated to Water Circuit". Please refer to the Electical Wiring Rules (AS/NZS 3000) and local statutes and regulations as to whether equipotential bonding is necessary.
Page 8
Operation Priming Pump: a) In a flooded suction system (water source higher than pump), the pump will fill itself with water when suction and discharge valves are opened. Water will be at the top of the hair and lint pot lid. b) If pump is not in a flooded suction system, unscrew and remove hair and lint pot lid;...
Service & Maintenance If water is seen to be leaking from directly underneath motor and casing, have pump serviced immediately. This indicates a leaking mechanical seal. Failure to fix this may result in premature product failure. NOTE: Onga recommend the use of silicon based lubricant on all ‘O’rings. The only routine maintenance needed is inspection/cleaning of leaf basket.
Removal of Pump for Servicing Switch off power and remove plug from power point. If the pump is hard wired into any other controls such as time clocks or automatic heads etc., THE WIRING SHOULD BE REMOVED BY A QUALIFIED ELECTRICIAN. Close control valves and undo barrel unions from suction and discharge lines.
Trouble Shooting Guide SYMPTOM CAUSE REMEDY Pump does not Run No Power at the power outlet Use another electrical appliance that is known to work to check the power point. Blown Fuse. Check Fuse and replace if necessary Automatic Thermal Overload has Switch the power to the pump off and allow the motor to cool before tripped to protect the motor.
Trouble Shooting Guide SYMPTOM CAUSE REMEDY Lack of water Ensure the water level in your pool is at least up to the halfway mark at the skimmer opening. Debris in the pump or skimmer Ensure that both the hair & lint pot basket and skimmer basket are Note: Do not operate pump with- free of leaves and other debris.