Installation

Pump Discharge/Outlet
Drain plug
The fittings on these pool pumps are constructed of ABS. Some PVC jointing
compounds are incompatible with ABS possibly causing failure to the product.
Check compound suitability prior to use.
All glued fittings and pipe work should be allowed to dry to atmosphere for
24 hours before closing installation. Failure to do so could cause injury or
installation failure.
Barrel Unions are to be hand tightened ONLY, to prevent damage occurring from
over-tightening.
Pump Mounting should be:
1) Pump position must be: Solid - Level - Rigid -Vibration Free. Pump should be
fixed to its support using bolts through the slots on the pump base.
2) Allow pump suction inlet height to be as close to water level as possible.
3) Allow for use of a piece of short, straight suction pipe into the suction port of the
pump (minimum length for 40mm diameter suction = 160mm; 50mm diameter
suction = 200mm) in order to minimise water turbulence entering the pump.
Pump Discharge/Outlet
Mounting holes
5
Equipotential bonding terminal