Airpax Dimensions MIL-24/2600Q Owner's Manual

Dc to ac power inverters

Advertisement

Quick Links

121473B
Airpax Dimensions, Inc.
4467 White Bear Parkway
(651) 653-7000
St. Paul, MN 55110-7626
Fax (651) 653-7600
OWNER'S MANUAL
FEBRUARY 2007
ISO 9001:2000 Certified Company
Airpax Dimensions, Inc.
DC to AC Power Inverters
OWNERS MANUAL for Models:
MIL-24/2600Q
MIL-24/3200DQ
Form 121473

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MIL-24/2600Q and is the answer not in the manual?

Questions and answers

Summary of Contents for Airpax Dimensions MIL-24/2600Q

  • Page 1 121473B Airpax Dimensions, Inc. 4467 White Bear Parkway (651) 653-7000 St. Paul, MN 55110-7626 Fax (651) 653-7600 OWNER'S MANUAL FEBRUARY 2007 ISO 9001:2000 Certified Company Airpax Dimensions, Inc. DC to AC Power Inverters OWNERS MANUAL for Models: MIL-24/2600Q MIL-24/3200DQ Form 121473...
  • Page 2 CAUTION: Working in the vicinity of lead-acid OWNERS MANUAL batteries is dangerous. Batteries generate explo- FOR AIRPAX DIMENSIONS sive gases during operation. There is a risk of INVERTERS acid exposure. There is also a risk of high current discharge from shorting the battery that can cause fire and explosion.
  • Page 3 an external AC power source is applied to the DC Input Wire Lengths (maximum) inverter’s AC outlet or its hardwire output. and Fusing Guide CAUTION: Be sure the inverter's circuit breaker or Distance(feet) fuse are turned "OFF" during installation. Model 1-10 11-15 16-20...
  • Page 4 switch. Connect the input terminal of the switch to 3.08.2 The 120 VAC output of the inverter is fused +24 VDC. The cable clamp strain relief should provided at the GFCI receptacle outlet on the inverter. be used to secure the field wires. 3.08.3 The 120/240 VAC output is presented 3.06.3 The switch should be mounted at a...
  • Page 5 5.03 Call Airpax Dimensions, Inc. for technical assistance and/or a return authorization number if the above steps are completed and the inverter still will not operate satisfactorily.
  • Page 6 FIG. 1 INSTALLATION WIRING WARNING: CONNECTING THE BATTERY WITH THE WRONG POLARITY TO THE INVERTER WILL CAUSE DAMAGE THAT IS NOT COVERED UNDER THE WAR- RANTY. FUSE REMOTE OUTPUT EARTH GROUND EARTH GROUND REMOTE SWITCH FUSE +24 FROM BATTERY CUSTOMER INSTALLED OPTION Page 6...
  • Page 7: Limited Warranty

    Lading and Delivery receipt with damage noted therein must accompany any claims for freight damage. Claims for shortage and lost shipments must be made in writing to Airpax Dimensions, St. Paul, MN within 10 days of date of shipment. Claims not reported within this time frame will not be honored.