Airpax Dimensions 12 Owner's Manual

Dc to ac power inverters

Advertisement

Airpax Dimensions, Inc.
4467 White Bear Parkway
St. Paul, MN 55110-7626
OWNERS MANUAL
Airpax Dimensions, Inc.
DC to AC Power Inverters
Form 121096
(651) 653-7000
Fax (651) 653-7600
ISO 9001:2000 Certified Company
OWNERS MANUAL for Model:
12/1200
INCLUDING OPTIONS:
A:
GFCI protected hardwire output
B: Battery Charger
R:
Remote Control /Status Lights
R2: Remote Control - Ground Start
T:
Transfer Switch
121096B
JANUARY 2007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Airpax Dimensions 12

  • Page 1 121096B Airpax Dimensions, Inc. 4467 White Bear Parkway (651) 653-7000 St. Paul, MN 55110-7626 Fax (651) 653-7600 OWNERS MANUAL JANUARY 2007 ISO 9001:2000 Certified Company Airpax Dimensions, Inc. DC to AC Power Inverters OWNERS MANUAL for Model: 12/1200 INCLUDING OPTIONS:...
  • Page 2 2. DESCRIPTION 1. General ....2.01 The inverter converts 12 to regulated 2. Description ... 120 VAC, 60 HZ, having a quasi-sine wave form.
  • Page 3: Model

    AC outlet or its hardwire output. Model 1-10 11-15 16-20 CAUTION: Be sure both the inverter and the 12/1200 4 ga 2 ga 1 ga external AC input circuit breaker or fuse (if needed) are turned "OFF" during installation. Fuse: 200A 250A 300A...
  • Page 4 4.02.1The battery charger voltage is ad- Output ("B" option) justable (Fig. 1). The factory setting is for a finish voltage of 13.8 VDC for 12. Rotating the potenti- Charging Rating ometer counter-clockwise lowers the finish voltage, Model Input @ 120VAC, 60Hz Output clockwise raises the finish voltage.
  • Page 5: Troubleshooting

    5.02.2 Make sure the inverter is turned "On", the output circuit breaker is reset and that the voltage is at least +12-volt at the DC input terminals. If not, check DC wiring connections and the line fuse. 5.02.3 Check the connection to the remote switch, if used.
  • Page 6 "R2" Option A.C. Output Ground start on one wire Output breaker External Power Customer Installed Option Inverter Power Low Battery Remote Switch - 12 Volt Overload Violet Wire Fuse High Temperature Charge Voltage Adjustment Red wire (+) Inverter Black wire (-)
  • Page 7: Limited Warranty

    Invoice, Bill of Lading and Delivery receipt with damage noted therein must accompany any claims for freight damage. Claims for shortage and lost shipments must be made in writing to Airpax Dimensions, St. Paul, MN within 10 days of date of shipment.

This manual is also suitable for:

1200

Table of Contents