PARAMETERS
(2) Method to directly input the torque command value as numeral value in digital
When "9999" is set in Pr.448, the input signal is considered as a torque command value.
Even if a value higher than 190H (400) is input, the torque command value is clamped at 400%.
7FFF
(7FF
H
26
Torque command value
400%
190
H
H
)
(400)
Most significant bit = 1
0
190
H
(400)
-400%
Most significant bit = 0
7FFF
H
Digital input signal
(7FF
)
H