4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (RAS-18SKP-ES, RAS-24SKP-ES)

No.
P
ar
ts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Switching Transformer (T01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C03)
9
Fuse (F01)
10
Varistor (R09, R10)
11
Resistor (R01)
1
2
Lou
v
er motor
13
Relay : (RY03)

4-2. Outdoor Unit (RAS-18SA-ES)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
T
ype
ICF-340-30-2B
———
SWT-77
TMP87CM40ANG-6P68
———
LC*SS11V-R06270
D3SBA60
EKMH451VSN121MQ35S
BET 6.3A
SR561K14DL
RF-5TK1R8
MP24Z3T
G5NB-1A-CA
Type
Output (Rated) 1500W, 2poles, 1 phase, 220 − 240V, 50Hz
PA200X2CS-4KU1 Winding resistance (Ω)
(at 20°C )
Output (Rated) 42W, 4poles, 1 phase, 220 − 240V, 50Hz
FG-240-42A
Winding resistance (Ω)
(at 20°C)
DS451305NPQB AC 450V, 3.0µF
B32332I5606J063
AC 450V, 50µF
220 − 240V, 50Hz
CLK-26J
– 10 –
FILE NO. SVM-09036
Specifications
DC 340V, 30W
10 kΩ at 25°C
DC7V, 12 V
10 kΩ at 25°C
27mH, 600mA
4 A, 600 V
120 µF, 450 V
6.3 A, 250 V
560 V
1.8Ω ,
5W
Output (Rated) 2 W, 6 poles, 1-2 phas e ,
DC 12 V
Coil DC 12V, 16.7mA, Contact AC 250V, 1A
Specifications
Red-Black
1.85
Red-Black
128
White-Black
2.62
White-Black
126

Hide quick links: