Cooling Operation; Fan Only Operation; Heating Operation - Toshiba RAS-18SKHP-ES Service Manual

Split wall type
Table of Contents

Advertisement

(3) The indoor heat exchanger restricts revolving
speed of the fan motor to prevent a cold draft. The
upper limit of the revolving speed is shown in
Fig. 7-3-8
T c
46
34
45
33
33
21
32
20
*A+0
*A+0
*A-8
*A-8
Fan s peed MANUAL or AUTO in s t a r t i n g
Fan s peed AUTO in s t a b i l i t y
* No limitation while fan speed MANUAL mode is in stability.
* A: When Tsc ≥ 24, A is 24, and when Tsc < 24, A is Tsc
Tsc: Set value
[In starting and in stability]
In starting
FAN
• Until 12 minutes
AUTO
passed after operation
start
• When 12 to 25 minutes
passed after operation
start and room temp.
is 3°C or lower than
set temp.
FAN
• Room temp. < Set
Manual
temp.–4°C
Fig. 7-3-8 Cold draft preventing control
(4) In order to prevent cold draft when compres s or
during heating operation.T hen louver will move
to upper pos ition and fan s peed will reduce or
OF F .
Fan s peed AUT O
F an s peed MANUAL
L-H (Up to
Normal AUT O
s etting s peed)
Line-approximate
Line-approximate
H and SL with T c.
H and SL with T c.
SL (W2)
SL (W2)
Stop
Stop
In stability
• When 12 to 25 minutes
passed after opeartion
start and room temp.
is than (set
)
3°C
between preset
• When 25 minutes or
more passed after
operation start
• Room temp.
Set
temp. –3.5°C
7-3-5. Automatic operation
([MODE] button on the remote control is set
to the automatic operation.)
(1) One of 3 operations (Cooling, Fan only or Heating)
is selected according to difference between the
preset temperature and the room temperature at
which the automatic operation has started, as
shown in Fig. 7-3-9. The Fan only operation
continues until the room temperature reaches a
level at which another mode is selected.
(2) Temporary Auto
When the [RESET] button on the indoor unit
is pushed, the preset temperature is fixed at 24°C
and the indoor unit is controlled as shown in
Fig. 7-3-9.
°C

Cooling operation

0

Fan only operation

-1

Heating operation

Heat pump model Cooling model
- 24 -
FILE NO. SVM-09036
Fig. 7-3-9