Maps Flowchart For The Rs/6000 And Pseries Host Systems - IBM eserver 7210 Service Manual

025 external dvd-ram drive
Hide thumbs Also See for eserver 7210:
Table of Contents

Advertisement

MAPs Flowchart for the RS/6000 and pSeries Host Systems

Step 1
Does the
7210-025
power up?
no
Step 2
Electrical outlet
OK?
yes
Step 3
Power cable
OK?
yes
Shut the system down
and power off
Remove cover and
prepare unit
Step 4
Power supply
OK?
yes
no
Step 5
Fan OK?
Exchange
yes
fan
Step 6
no
Drive
OK?
Exchange
drive
Figure 2. Flowchart of the Maintenance Analysis Procedures (MAPs) for RS/6000 and pSeries Host Systems
10
7210 DVD-RAM Drive Service Guide
Was the SCSI
yes
address set
correctly?
Shut the system down
no
and power off
Contact service
personnel
Remove cover
no
Exchange
power cable
Was the SCSI
address switch
plugged into
Did drive
complete
no
Exchange power
supply
voltages?
Exchange power
yes
Step 7
no
yes
Step 8
no
drive?
yes
Step 9
yes
POST?
no
Step 10
Good
Check
Exchange
drive
Bad
supply
Step 11
Reassemble
Step 12
Check external SCSI
bus cable connection
Step 13
Check terminator
installation
Step 14
Run Configuration
Manager
Step 15
Fail
Run AIX
diagnostics
Replace FRU/contact
service personnel
Pass
Problem fixed
RBBTP502-1

Advertisement

Table of Contents
loading