Door Removal; Fuel Conversion; Blower Removal - Lennox Hearth Products Merit Series Installation And Operation Manual

Medina direct-vent gas fireplace inserts
Hide thumbs Also See for Merit Series:
Table of Contents

Advertisement

Glass Door Removal
CAUTION: Do not slam or strike glass door or damage may
occur.
Do not remove the glass door while the insert is hot. To remove the glass
door, pull forward and up on the top latches. Lift the glass door up and
off the lower spring latch. Be careful not to damage or scratch the glass
while handling. To reinstall the glass, reverse the removal steps. Do not
operate the insert with the glass removed.
(A) Spring Handle Latches
(B) Door Mounting Plates
Figure 20
Glass Door Cleaning And Repair
Cleaning: Do not remove or clean the glass door when hot. A gas door
glass cleaner (available from your Lennox Hearth Products dealer) or a
household glass cleaner should be used with a soft cloth to clean the
glass. Do not use an abrasive cleaner.
Repair: If the glass is broken in the glass door, the entire door (metal
frame, gasket and glass) should be replaced as a unit. This replacement
unit is available from your Lennox Hearth Products dealer. Do not use
substitute parts or materials.
CAUTION: Do not operate this insert with broken glass.
Blower Wiring
Schematic
From Power Source
Figure 21
18
Green (Ground)
Black (Hot)
White (Neutral)
Blower
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Fuel Conversion
Converting your Medina™ gas insert between natural gas and LP can
be accomplished by installing a conversion kit (valve regulator and
burner orifice). Only a qualified service technician should perform the
conversion.
Conversion Kit: Please see instructions provided with conver-
sion kit.
Blower Removal
Unplug the power supply cord from the electrical outlet prior to remov-
ing the blower. The blower can be accessed through the back wall of
the firebox.
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing (see the blower
wiring diagram below for reference).
Remove the insert face, glass door and log set. All of these items are fragile
so handle them with care. Next, remove the nine allen head screws around
the outside of the panel fastened to the back wall of the firebox. Rotate the
top of this panel toward the front, remove the two wires connected to the
blower and then lift the panel with the blower attached out of the firebox.
To reinstall the blower, repeat these steps in the reverse order.
Electrical Requirements:
This gas insert operates without an outside power source, however the
blower requires a 120 Volt electrical service outlet. This appliance, when
installed, must be electrically grounded in accordance with local codes,
or in the absence of local codes, the National Electrical Code ANSI/NFPA
70 - latest edition. (See Operating Options for thermostat and ON/OFF
switch information).
Blower Snap Switch
Speed Control
White
Black

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merit medina

Table of Contents