Lennox Hearth Products Direct-Vent Gas Installation And Operation Manual

Lennox Hearth Products Direct-Vent Gas Installation And Operation Manual

Direct-vent gas fireplace insert merit series

Advertisement

Retain These Instructions For Future Reference
I
n the Commonwealth of Massachusetts:
• Installation must be performed by a licensed plumber or gas fitter
• See Table of Contents for location of additional Commonwealth of
Massachusetts requirements
Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will
retain heat for a while after shutting off the appliance. Severe burns may result.
Carefully supervise children in the same room as appliance.
Suitable for installation into masonry or factory built fireplaces. These appliances may be installed in an after-
market permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance
is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with
other gases unless a certified kit is used.
Lennox™ gas-burning appliances are designed for use as a supplemental heater. They are not intended for
continuous use as a primary heat source.
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury or loss
of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas supplier's
instructions.
• If your gas supplier cannot be reached, call
the fire department.
Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier
INSTALLATION AND OPERATION MANUAL
Direct-Vent Gas
Fireplace Inserts
P/N 775,221M Rev. A, 05/2007
A French manual is available upon request. Order P/N 775,221CF.
Ce manuel d'installation est disponible en francais, simplement
en faire la demande. Numéro de la pièce 775,221CF.
.
Report No. 050-S-18b-5
WARNINGS
AVERTISSEMENT: Assurez-vous de bien suivre les instruc-
tions données dans cette notice pour réduire au minimum
le risque d'incendie ou d'explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser d'essence
ni d'autres vapeurs ou liquides inflammables à proximité de
cet appareil ou de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une odeur
de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur.
• Ne pas vous servir des téléphones se trouvant dans le bâti-
ment
• Appelez immédiatement votre fournisseur de gaz depuis un
voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service des incendies.
L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
Medina™ (MED)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Direct-Vent Gas and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lennox Hearth Products Direct-Vent Gas

  • Page 1 • If your gas supplier cannot be reached, call the fire department. Installation and service must be performed by a quali- fied installer, service agency or the gas supplier INSTALLATION AND OPERATION MANUAL Direct-Vent Gas Fireplace Inserts P/N 775,221M Rev. A, 05/2007 Report No. 050-S-18b-5 WARNINGS AVERTISSEMENT: Assurez-vous de bien suivre les instruc- tions données dans cette notice pour réduire au minimum...
  • Page 2: Table Of Contents

    & s ... 3 autions afety rifiCe ltitude djustment ... 4 ireplaCe equirements & a ... 4 odes pprovals equirements ...6-8 nstallation ... 6 eatures ... 6 aCkaging ... 6 atings & f nsert ireplaCe imensions learanCes to ombustibles ... 8 nsert eveling ...
  • Page 3: Autions Afety

    FOR YOUR SAFETY do not install or operate your  Medina™ gas insert without first reading & understand- ing this manual. Any installation or operation of the appliance deviating from that which is stated in this manual WILL void the warranty & may be hazardous. INSTALLATION &...
  • Page 4: Orifice Size/Altitude Adjustment

    Orifice Size/Altitude Adjustment For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice should be de-rated by 4% for every 1,000 feet to maintain the proper ratio of gas to air. Improper orifice sizing may result in damage and unsafe conditions. Chang- ing the orifice should only be done by a qualified service technician. Contact your Lennox Hearth Products dealer for proper orifice sizes. The Medina™ Insert • Must conform with all local, state, and national installation codes. In the absence of local codes, the installation must conform with National Fuel Gas Code ANSI Z223.1 - latest edition, also known as NFPA 54 (In Canada, the current CAN/CSA B149.1 installation code). Refer to the National Fuel Gas Code and local zoning and code authorities for details on installation requirements. • Must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (in Canada CAN/CSA Z240 MH), or when such a standard is not applicable, the Standard for Manufactured Home Instal- lations, ANSI A225.1 - latest edition for manufactured (mobile) home installations.
  • Page 5: Equirements Or He Ommonwealth Of Assachusetts

    Commonwealth Of Massachusetts Requirements Note: The following requirements reference various Massachusetts and national codes not contained in this document. For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: Installation Of Carbon Monoxide Detectors At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas-fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas-fitter shall observe that a bat- tery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.
  • Page 6: Nstallation

    Pre-Installation eatures Installation Options Residential - Vented Vertical Only Manufactured (Mobile) Home N atural Gas Or Propane (LP) Bedrooms Optional Wall-mounted Or Remote Thermostat Electrical The fan motor requires 120 Volts AC for operation. The fireplace is not dependent on the fan or an outside electrical supply to operate. Millivolt Valve This insert is operated with a millivolt valve and therefore burns even during a power outage. Fuel This insert comes from the factory equipped to burn natural gas at a specified elevation. The insert can be converted to burn LP (liquid propane) by installing a conversion kit. Only Lennox Hearth Products conversion kits can be used to convert from NG to LP or LP to NG. Contact your Lennox Hearth Products dealer for details.
  • Page 7: Nsert Ireplace Imensions

    nsert imensions 31-1/4”(794mm) Air Intake 16”(406mm) 7-1/4” (184mm) 14-1/2” (368mm) 13” (330mm) Figure 1 15-1/4” (387mm) 17-1/4” (438mm) 7-1/2” (191mm) Figure  Side View Insert Dimensions Width of insert behind Surround Panels Rear height Insert depth into fireplace Flue center line from back of surround with 45º collar Flue center line from back of surround with 90º...
  • Page 8: Clearances To Combustibles

    Clearances to Combustibles inimum learanCes to ombustibles E = 31-1/2" (800mm) from Top Facing to Bottom of Insert F = 25-1/2” (648mm) from Center of Glass to Side Facing or Side Wall J = 39” (991mm) from 10.5” (267mm) Mantel to Bottom of Insert earth roteCtion G = Minimum Hearth Protection from Front of Insert* H = Vertical Distance from Insert Bottom to Combustible Material. 13”(330mm) 0”(0mm) Note: Hearth protection to be min. /8” (10mm) thick non- combustible or equivalent, with a k factor of .84.
  • Page 9: Enting Nstallation

    Installation enting nstallation Your Lennox™ gas insert must be vented to the outside in accordance with the current edition of the National Fuel Gas Code ANSI-Z223.1 (In Canada, the current CAN/CSA B149.1 installation code). The insert must not be connected to a chimney flue serving a separate solid fuel burning ap- pliance. This gas insert requires a 3” diameter listed flex liner. The vent should terminate with a listed direct vent termination cap. The chimney should be sealed around the cap to pre- vent air and rain from entering the chimney. Adhere to the vent manufacturer's instructions for installation and vent termination. These appliances are approved for use with the following vent kits. Vent Kits * Cat. No. Model Description H0909 FKDVI Flex Liner Kit, DVI 3” X 35’...
  • Page 10: Z Ero C Learance F Ireplace I Nstallation

    learanCe ireplaCe nstallation This insert may be installed in a masonry or factory built/zero clearance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be removed and the ZC damper must be removed or secured open. The ZC doors, screen, refrac- tory or masonry lining, baffles, and smoke shelf may be removed if necessary to install the gas insert. However, do not cut or alter the fireplace components. The removal of any parts to facilitate installation must not alter the integrity of the inner or outer shells of the fireplace cabinet. Any parts removed must be replaceable if the insert is taken out of the fireplace or the fireplace must be clearly marked with the metal label that states: "This fireplace has been altered and is no longer safe to operate." The insert is designed to fit into a ZC fireplace with a minimum firebox height of 17-1/4" (438mm). To facilitate this the hood will need to be removed and discarded (Note: The screws should be replaced in the insert body). Installation of the flue collar is removable (see Flue Collar Connection). If the factory-built fireplace has no gas access hole(s) pro- vided, an access hole of 1-1/2" (37.5 mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner. This access hole must be plugged with a non-combustible insulation after the gas supply line has been installed. The installer must mechanically attach the marking supplied with the gas fireplace insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed.
  • Page 11: Urround Anels Nstallation

    Front Logs Install front logs on retainer slots. Figure 10 Place top log on pin. Top Log Ports Figure 11 urround anels nstallation The Medina insert surround panels is made of heavy gage steel for durability and, if desired, for the ease of making an inside fit in the fireplace. 1. Remove the speed nuts (A in Figure 12) from the parts bag and install (with the flat surface forward) on the six holes in the surround brackets - three on each side of the insert (B in Figure 12). A flat bladed screwdriver may help in installing the nuts. 2. Install all surround panels and trim with the insert po- sitioned in the fireplace but a few inches in front of its final location. 3. Install the side surround panels by lining up the holes in the tabs on the side surround panels in front of the holes on the surround brackets. Next insert two slotted 1/4" truss screws for each side surround panel and secure loosely. 4. Fasten top surround panel with the remaining two truss screws. Tighten all six truss screws after adjusting the surround panels to eliminate space between side and...
  • Page 12: Gas Line Installation

    Gas Line Installation After leveling, position the insert in the fireplace - holding it about six inches out from its final location. Caution: Specific hearth requirements apply (see Clear- ances to Combustibles). The Medina™ gas insert must be connected to the gas line in accordance with local codes and/or the National Fuel Gas Code, ANSI Z223.1 (In Canada, the current CAN/CSA B149.1 installation code). The insert comes with an 8" nipple at- tached to the supply side of the gas valve. After connecting the gas line, all joints in the line and connections at the valve should be checked for leaks with a gas leak test solution before final positioning of the unit. ressure equirements A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES IS IMPROPER GAS PRESSURE! The most important item to check during the initial installation and the first thing to check when operating problems occur is gas pressure! This appliance will not function properly unless the required gas pressure...
  • Page 13: Lighting Instructions

    See Detail Shutter Figure 14 Adjustment Moving shutter bracket to the right will open shutter, to the left will close shutter. Figure 15 Shutter Adjustment Detail Operating Instructions ighting heCklist Be sure to check these items before the initial lighting of the insert: The insert gas label corresponds to the gas supply avail- able - that is "natural gas" for natural gas or "LP gas" for LP gas. Gas pressure has been checked carefully - see Page 12. All gas fittings have been checked for leaks. c All clearances to combustibles have been met-see Page 8. c All combustible materials have been removed from the c area in front of the insert.
  • Page 14: To Turn Off Gas To Appliance

    5. Locate the pilot by looking over the top of the left front log. A blue flame will be seen when the pilot is lit. 6. Turn the gas control knob counter-clockwise to the "PILOT" position. 7. Push the knob all the way in and hold in that position. Immediately light the pilot by pressing the igniter button several times until pilot is lit. Continue to hold the knob in for about 30 seconds after the pilot is lit. Realease knob and it will pop back out. Pilot should remain lit. If it goes out, repeat steps 4-8 holding knob in an additional 15 seconds after pilot is lit. If knob does not pop out when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or your gas supplier. 8. After pilot is lit, turn gas control knob counter-clockwise to "ON." Knob can only be turned to "ON" if the knob has popped out. 9. To turn burner on, turn "ON/OFF" rocker switch to "ON" or set the thermostat to the desired temperature above room temperature.
  • Page 15: Paint Curing

    Paint Curing This insert has been painted with StoveBright high tem- perature metallic stove paint. It leaves the factory dry to the touch, but finishes curing as the insert is used. Fire the insert four successive times for ten minutes each time with a five minute cool down between each firing. Ventilate the house during these first firings as the paint gives off an unpleasant odor. It is recommended that persons sensitive to an imbalance in the indoor air quality avoid the insert during the curing process. Quiet Operation As the Medina™ gas insert is burning, a number of normal operational sounds may be heard. The flow of gas through the gas valve and orifice may make a rushing or whistling noise.
  • Page 16: Perating Ptions

    A wall-mounted switch, a millivolt wall thermostat, or a remote control, can be used to supplement the rocker switch. The gas valve is powered by millivolts generated by the pilot assembly. This millivolt system is very sensitive to electrical resistance, therefore, make sure all connections are tight, clean, and free from corrosion. Do not splice any millivolt wires. Consult the table on this Page to determine the proper gage of wire for the thermostat or wall switch connections. This table refers to the total length of the wire (out to the switch and back). The thermostat must be a millivolt type. A 24-volt furnace thermostat will not work. Never hook up household current - 120 Volts - to the mil- livolt system. It is not recommended to hook up any more than two switches to the insert (for example a rocker switch and a wall thermostat). Additional switches may affect the system resistance and increase the chance of the burner not igniting. Follow the instructions included with the thermostat or remote control for wiring. Millivolt Control Schematic Piezo Igniter...
  • Page 17: Maintenance And Servicing

    Maintenance & Servicing aintenanCe heCklist The following should only be performed by a qualified service technician. Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 1. Annual inspection should be made and the following checks performed: oWhen unit is cool, remove glass and inspect burner for dirt, soot, and lint accumulations, and remove if neces-...
  • Page 18: Oor Emoval

    lass emoval Caution: Do not slam or strike glass door or damage may occur. Do not remove the glass door while the insert is hot. To re- move the glass door, pull forward and up on the top latches. Lift the glass door up and off the lower spring latch. Be careful not to damage or scratch the glass while handling. To reinstall the glass, reverse the removal steps. Do not operate the insert with the glass removed. (A) Spring Handle Latches (B) Door Mounting Plates Figure 0...
  • Page 19: Roubleshooting

    Troubleshooting NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas sup- ply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 20: Replacement Parts

    Replacement Parts Medina™ (MED) Part Number Description H6033 Cassette Assembly, NG (if LP, also requires H5464 conversion kit) H3070 Main Burner Assembly H5922 Pilot Assembly, Convertible NG or LP H5938 Gas Control Valve, NG (if LP, also requires H5941 regulator kit) H5939 Regulator, NG H5941 Regulator, LP H5965 Orifice, Main Burner, NG #41 H5953 Orifice, High Altitude, Main Burner, NG #42 H5964 Orifice, Main Burner, LP #53 H5951 Orifice, High Altitude, Main Burner, LP #54 H5464 Conversion Kit, NG to LP H5465 Conversion Kit, LP to NG H6013 Blower w/Mounting Bracket H5875 Blower Snap Switch H5655 Blower Speed Control (rheostat) H5744 On/Off Switch H6007 On/Off Switch Wires H5745 Piezo Igniter...
  • Page 21: Safety / Listing Label

    SAFETY / LISTING LABEL MODEL MEDINA™ MODÈLE MANUFACTURED BY / FABRIQUÉ PAR: LENNOX HEARTH PRODUCTS PO BOX 987 Report No. / Número de Rapport AUBURN, WA., USA 98071 050-S-18b-5 FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED. CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL.
  • Page 22: To Turn Off Gas To Appliance

    Lighting Label FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, INJURY OR LOSS OF LIFE. CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, FURNITURE, GASOLINE AND OTHER LIQUIDS WITH FLAMMABLE VAPORS AWAY.
  • Page 23: Warranty

    WARRANTY Your gas insert is covered by a limited warranty (provided with appliance). Please read the warranty to be familiar with its coverage. Retain this manual. File it with your other documents for future refer- ence. PRODUCT REFERENCE INFORMATION We recommend that you record the following important information about your fireplace. Please contact your Lennox Hearth Products dealer for any questions or concerns. For the number of your nearest Lennox Hearth Products dealer, please call 877-247-3673. REPLACEMENT PARTS See Page 20 for a complete replacement parts list. Use only parts sup- plied from the manufacturer. Your Fireplace Insert's Model Number _ __________________________________ Your Fireplace Insert’s Serial Number ___________________________________ The Date On Which Your Fireplace Insert Was Installed _ _____________________ The Type of Gas Your Fireplace Insert Uses _______________________________ Your Dealer's Name _________________________________________________ Fuel Type (Check one) c Natural Gas c Propane Gas (LP) Normally, all parts should be ordered through your Lennox Hearth Products distributor or dealer. Parts will be shipped at prevailing prices at time of order.
  • Page 24 Lennox™ reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © Lennox Hearth Products 007 P/N 775,1M REV. A 05/007 1110 West Taft Avenue • Orange, CA 985...

This manual is also suitable for:

Merit medina

Table of Contents