72-8795 PROGRAMMABLE DC POWER SUPPLY User's Manual 405 S. Pioneer Blvd Springboro, OH 45066 mcmelectronics.com...
Page 2
72-8795 Programmable DC Power Supply Series PROGRAMMABLE DC POWER SUPPLY Thanks for using our products. Please read this manual thoroughly before operation.
GENERAL MAINTENANCE CONTENTS [Step 3] CONTENTS After zeroing the voltage of the three channels, which are also saved, move the cursor to [CURRENT] of [CH1]. Connect the ammeter and adjust the knob to make the current reading equal 0MA. Then press [ENTER] to store the calibration Safety Symbols data of the corresponding channel.
GENERAL MAINTENANCE SAFETY SYMBOLS Safety Symbols 2. Adjustment And Calibration 2.1.1 Preparation a. Power unit on and allow 30 minutes to warm up before calibration. b. Ambient temperature: 23±5°C, Humidity: Less than RH80%. WARNING: Warning statements identify conditions or practices to avoid c.
PARA 3 2 . 0 0 V 3 . 0 0 0 A PARA 72-8795 Programmable Power Supply is controlled by a Micro Processor SERIES 0 6 . 0 0 V 3 . 0 0 0 A Unit (MPU) that is designed for a communication interface by RS-232 or USB to computer to enable advanced testing and power delivery by programmable control.
Note: The following indexes are tested after unit being powered for 20 minutes. of the last step in the sequence to be used and press [AUTO], and a box Specifications 72-8795 should appear after the value. After the automatic sequence reaches this step, it 0~32V 2, will return to the first step and continuously repeat the sequence.
OPERATION TECHNICAL SPECIFICATIONS Example: Set current at 1.500A. Voltage≤0.05%+20 mV Press [I SET][1][.][0][0][0][ENTER] Accuracy Current≤0.1%+20 mV If the load current through output terminals exceeds the setting value, the Parallel Voltage≤5mA Load regulation Simultaneous instrument will operate in the C.C. mode; if load current does not exceed the Current≤6mA Operation setting value, the instrument will operate in the C.V.
2. Output Current Setting: Select the desired channel by pressing [SHIFT][CH#] to set the cursor 17 17 72-8795 to toggle that channel. PROGRAMMABLE DC POWER SUPPLY Method 1: Set output current by pressing [I SET] and using number keys to key in 19 19 [current value], then press [ENTER].
FUNCTION LAYOUT FUNCTION LAYOUT Layout of Rear Panel Change incremental tuning value of the rotary knob; [SHIFT][Step] to change the incremental steps F/C (STEP) of the rotary knob Recall the stored settings; [SHIFT][STORE] to edit and save channel settings. RECALL(STORE) Toggles automatic execute mode;...