Craftsman 919.165612 Owner's Manual page 14

Permanently lubricated twin v 2-stage stationary air compressor
Hide thumbs Also See for 919.165612:
Table of Contents

Advertisement

Available languages

Available languages

Check Valve: When the air
compressor is operating, the check
valve is "open", allowing compressed
air to enter the air tank. When the
air compressor reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
Pressure Release Valve: The
pressure release valve, located on
the side of the pressure switch, is
designed to automatically release
compressed air from the compressor
head and the outlet tube when the
air compressor reaches "cut-out"
pressure or is shut off. The pressure
release valve allows the motor to
restart freely. When the motor stops
running, air will be heard escaping
from this valve for a few seconds.
No air should be heard leaking when
the motor is running, or continuous
leaking after unit reaches "cut-out"
pressure.
Air Intake Filter (not shown) This
filter is designed to clean air coming
into the pump. This filter must
always be clean and ventilation
openings free from obstructions. See
"Maintenance".