No.
Part name
High voltage
1) Follow to the procedure in the item
2
generator
2) Remove the drain guide.
3) To remove the air ionizer from the back body,
4) Disconnect the connectors of the high-voltage
5) Remove the fixing screw which secures the
<How to assemble the high voltage generator>
1) Insert the high voltage generator straight into
2) Pass the leads of the high voltage generator
3) Attach the air ionizer to the back body, and
4) Attach the drain guide.
Procedures
pull it toward you while pressing down on its left
and right claws.
Disconnect the two leads (black) connected to
the air ionizer from where they are fitted into
the other components.
(Caution: do not remove the Faston.)
generator, and disconnect the four leads from
where they are fitted into the other compo-
nents.
high voltage generator, and remove the high
voltage generator from the evaporator.
Press the
claw here
the evaporator, and secure it using the fixing
screw.
through the area designated and insert them
into its connectors.
pass the two leads (black) through the area
designated on the electric parts box assembly.
.
1
Press the
claw here
Pull here
– 100 –
Remarks
Connector
Drain guide
Air ionizer
Screw
Check whether the
Check whether the
leads have been
leads have been
completely inserted.
completely inserted.
completely inserted.
Claw
Claw
Claw
Claw
Claw
Claw