Samsung Techwin. Disclaimer Samsung Techwin makes the best to verify the integrity and correctness of the contents in this document, but no formal guarantee shall be provided. Use of this document and the subsequent results shall be entirely on the user’s own responsibility.
Page 3
Before operating the camera, confirm the camera model and correct input power voltage. To help you understand this manual thoroughly, we’ll introduce our model description. ■ SCB-9060/9080 SERIES • NTSC MODEL • PAL MODEL SCB-9060/9080N SCB-9060/9080P ■ MODEL DESCRIPTION • SCB-9060/9080X SIGNAL SYSTEM •...
Safety information CAUTION fi RISK OF ELECTRIC SHOCK. DO NOT OPEN TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE CAUTION: COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.
Page 5
Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or containers fi lled with water on top of the camera. doing so may cause personal injury due to fi re, electric shock, or falling objects. Do not install the unit in humid, dusty, or sooty locations. doing so may cause fi re or electric shock.
Safety information FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : This device may not cause harmful interference, and This device must accept any interference received including interference that may cause undesired operation.
Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall be placed on the apparatus Samsung Techwin cares for the environment at all product manufacturing stages to preserve the environment, and is taking a number of steps to provide customers with more environment-friendly products.The Eco mark represents...
Introduction FEATURES Thermal Night Vision Camera The SCB-9060/9080 Thermal Night Vision Camera is a contactless monitoring device capable of measuring the surface temperatures of all target areas, and displaying the resulting data via temperature distribution images (thermal images). Featured by the top-notch uncooled IR detector, the sensor does not require you to prepare a separate cooling device or maintenance.
Introduction WHAT’S INCLUDED Check if the following items are included in the product package. Thermal Night Vision Camera SCB-9060 SCB-9080 A ( ) SCB-9060/9080, User Manual Set of Wrench (x3) camera sun shield Lens cap Bracket Screws (x2) Camera Holder Screws (x4) ➊...
COMPONENT NAMES AND FUNCTIONS Names of external camera parts ➊ ➋ ➎ ➌ ➍ ➊ Lens (SCB-9060 : 14mm, SCB-9080 : 50mm) ➋ Sun Shield ➌ Video signal/communications(RS485) cable ➍ Power cable(AC24V,50/60Hz)/ALARM Port ➎ Support platform for fastening camera...
Page 12
Introduction Rear Terminal Placement ① ② ④ ③ ① POWER LED • Power ON : Lit • Abnormality/Warning : Flashing ② Function Setup switch ③ Terminal Block A Name Explanation TRX+ RS485 + Communications Non-inverting input/output TRX- RS485 - Communications Non-inverting input/output VIDEO Output of video signal Earth-grounding of video signal...
Page 13
Connector specifications and signals Function Explanation Notes Because Half-duplex communication Communication terminator settings: is supported, this function is used to - Default value: ON RS485 I/F update F/W. - If multiple cameras are installed : (TRX+, TRX-) Standard users should utilize the Turn only the camera measuring the same cables as those employed at furthest distance ON, and the...
Page 14
Introduction Assembly/Adjustment Methods Ø90 ❶ ➋ * De Ø90 ❶ ➋ ❶ A screw to fix the focus is located on the bottom of the lens. ➋ A sun shield is provided with this camera to allow for outdoor installation. Using the bolts and hexagon wrenches included in this package, fasten the camera unit and sun shield firmly in place.
As a result, thermal images will not display consistently for several seconds. Menu controls can be used to save values to be applied at subsequent start-up of the SCB-9060/9080. NUC(non uniformity correction) This device will perform a calibration necessary for imaging (NUC) after the internal shutter closes.
Installation MONITOR/COMMUNICATIONS CONNECTION Connecting the Monitor Connect the video output terminal on the rear of this product to the monitor. IR camera Monitor 1. D 2. F Refer to the owner’s manual for each device. Connection methods employed may differ depending on the monitors and peripheral devices used.
1. Do not adjust the focus if there is no particular point of focus to monitor. 2. For an in-depth explanation of the controls used with the SCB-9060/9080, refer to the section detailing how the camera is operated on page 18.
Setup MENU CONFIGURATION Main Menu ● ● ● COMM RANGE UNIT ● ● ● SYSTEM TV TYPE LANGUAGE INFO ● ● RESET RETURN ● ● ● MODE INSTANT NUC RETURN ● ● ● TEMP AREA TYPE ALARM OUT ALARM ● ●...
Page 19
28.0 MAIN MENU 28.9 ► SYSTEM Select the function using the Function Setup switch. ALARM IMAGE COLOR DISPLAY 21.5 EXIT Main setup menu is displayed on the monitor screen. Select a desired function using the Function Setup switch. Press the Function Setup switch to move the cursor (arrow) in a desired position.
Page 20
Setup Baud Rate : Select one from 2400/4800/9600/ 19200/38400/57600/115200. (Default : 9600bps) COMM. MODE : Select a parity bit from NONE/EVEN/ODD. (Default: 8-N-1) Return Packet: Specify the return packet. Terminal: Specify the termination resistor for RS485 communications. RETURN : Save your settings and return to the SYSTEM menu. TEMP RANGE : Specify the temperature range for the incoming video signal.
Page 21
NUC (Non-uniformity Correction) regulates different characteristics of the screen pixels, which results in reproduction of a sharper and clearer image. When the SETUP menu screen is displayed, MAIN MENU select ‘LENS’ by using the Function Setup SYSTEM switch so that the arrow indicates ‘NUC’. ►...
Page 22
Setup TYPE : Specify the display of temperature area to either LINE or AREA. ALARM OUT : Set “ALARM OUT” to “ON/OFF”. If a target appears between the upper and lower limits for tripping the alarm in each area, the alarm will be activated.
Page 23
DZOOM : Confi gure the digital zoom settings for the camera. You can set the zoom factor to up to x4. You can move to a sub menu item and change the zoom factor or zooming area to your preference. ROTATION : Flip or rotate the image.
Page 24
Setup DISPLAY You can configure the OSD (On Screen Display) settings to your preference. When the SETUP menu screen is displayed, MAIN MENU select ‘LENS’ by using the Function Setup SYSTEM switch so that the arrow indicates ‘DISPLAY’. Press the Function Setup switch to move to the ALARM sub menu items as shown.
Factory Default Functions Set Value RANGE AUTO ℃ UNIT MODE AUTO INTERVAL TEMP AREA 1~8(OFF) TYPE AREA ALARM ALARM OUT HIGH : 100℃ LOW : 0 ℃ THRESHOLD CONTRAST SHARPNESS BRIGHTNESS IMAGE AE MODE MIN/MAX SSNR DZOOM ROTATION PALETTE CLOLR ISOTHERM CAMERA ID DZOOM MAG...
Troubleshooting TROUBLESHOOTING Check the points listed below if the product appears to be malfunctioning. If the problem continues, please contact the sales agent from whom the product was purchased. PROBLEM SOLUTION Verify that the power source is connected properly, and that the If nothing can be seen onscreen device is receiving power.
Specifications SPECIFICATIONS SCB-9060N SCB-9060P SCB-9080N SCB-9080P Video Imaging Device 320(H)x240(H) Uncooled Microbolometer Sensor Pitch 23.5μm Measured wavelength 8 ~ 14um, LWIR range Video Ratio ( Sensor ) 30fps 25fps 30fps 25fps Thermal Sensitivity(NETD) <80mK @ F1.0 Video Output CVBS 1.0 Vp-p / 75 composite, ITU-656 8bit Digital Output Lens Type Focal Length (Zoom Ratio) 14mm ( Fixed ) 50mm ( Fixed )
Page 28
Specifications SCB-9060N SCB-9060P SCB-9080N SCB-9080P Temperature Display Area Adjustable 8 Zone & Position Movable Cross Point ISOTherm Isolated Temperature Display Pseudo Color B/W, W/B, Color1, Color2 Selectable Temp Indicator Min/Max Scene Temperature with Color Bar Alarm Temperature Detection, 1 GPIO Alarm Output Communication RS-485, Coax(Pelco Coaxitron Compatible) SAMSUNG-T, SAMSUNG-E, PELCO-D, PELCO-P, BOSCH,...