Alignment Procedures - Medion B1770NSL Service Manual

17-inch color monitor
Table of Contents

Advertisement

MEDION

5-2 Alignment Procedures

5-2-1 High Voltage Adjustment
CONDITION
Display image : Crosshatch pattern
PROCEDURE
Connect DC meter to TP5 and adjust VR401 to obtain a DC voltage of -130 ± 0.2 V DC.
5-2-2 Screen and White Balance Adjustment
CONDITION
Press
and
buttons simultaneously when switching the power "On".
1
2
Bias VRs : VR961, VR901, VR931
Display image : No video
PROCEDURE
1
Raster color setting
1-a.
Set Brightness through OSD menu to -40 V at G1 and 560 V at G2.
1-b
Adjust VR961, VR901 and VR931 to maximum.
1-c
Adjust VR931 to raster just distinguish.
1-d
Set Brightness to maximun.
1-e
Adjust VR901 to get x=280 ± 5 and VR961 to get y=280 ± 5, brightness = 0.9 ~ 1.2 FL.
1-f
Adjust Brightness to cut-off.
CONDITION
Display image : 50 mm x 50 mm white block pattern
PROCEDURE
0
2
6500
K color temperature setting
2-a.
Set Brightness to cutoff and Contrast to maximum.
2-b
Move cursor on OSD to choose color temperature icon.
2-c.
Press
key to G gain then adjust G gain = 68 value, then adjust B, R to y=329±5, x=313±5.
2
2-d
Check x=313±5, y=329±5.
0
3
9300
K color temperature setting
3-a.
Set Brightness to cutoff and Contrast to maximum.
3-b
Move cursor on OSD to choose color temperature icon.
3-c.
Press
key to G gain then adjust G gain = 85 value, then adjust B, R to y=311±5, x=281±5.
2
3-d
Adjust contrast to set Y=38±2FL
3-e
Check x=281±5, y=311±5.
3-f
TCO99-model 9300
4
Full white ABL setting
CONDITION
Display image : full white pattern
4-a
Set Brightness to cutoff and Contrast to maximum.
O
K color temperature setting y=297±5, x=283±5.