(2) Remove the two retaining rings and remove the two platen shaft bearings, platen gear and
platen ASSY.
Platen shaft bearing
Retaining ring
Platen ASSY
Platen shaft bearing
Retaining ring
Platen ASSY
Fig. 3.1-6 Disassembling the Top Cover ASSY (2)
Top cover
Platen ASSY
* Remove the platen shaft bearing on the left and right sides.
* Remove the left end of the platen ASSY from the top cover.
III- 8
Top cover
Platen shaft bearing
Platen gear
Retaining ring
Platen shaft bearing
Platen gear
Retaining ring