6. 3 How to change the mode
Press the
button to change the mode to automatic, heating or cooling. The appropriate indicator light
will be illuminated on the right side of the control unit.
6.4 How to check the settings and the current measured values
In the standby mode or operation mode, use the buttons
measured values
Parameter
0
Setting the return water temperature (cooling mode)
1
Setting the return water temperature (heating mode)
2
Defrosting cycle
3
Setting the pipeline temperature for the start of defrosting
4
Setting the pipeline temperature for the end of defrosting
5
Maximum defrosting time
6
Number of systems
7
Restart after electricity supply failure
Type: only cooling 0/
heating and cooling 1/
8
heating and cooling + additional heating 2/
heating only 3
Different water pump operating mode
9
0 water pump works uninterruptedly
1 water pump works together with the heat pump
A
Setting the return water temperature (automatic mode)
B
Actual temperature of input water
C
Actual temperature of output water
D
Pipeline water temperature in system 1
E
Pipeline water temperature in system 1 (only for a double system)
F
Surrounding temperature
Meaning
Parameter 1
to fi nd the parameter 0-A and the current
or
Current measured value
9
Range
Factory setting
8-28ºC
12ºC
15-40ºC
40ºC
30-90 min
45 min
0- –30ºC
-7ºC
2-30ºC
13ºC
1-12 min
8 min
1-2
1
0-1
1 (yes)
0-3
1
0-1
0
8–60ºC
28ºC
-9 +90ºC
-9 +90ºC
-9 +90ºC
-9 +90ºC
-9 +90ºC
EN