Electrical Specifications
Important – Qualified and licensed electricians must perform all electrical
hookups in accordance with the National Electric Code. The following
specifications must be followed in order to ensure proper performance & safety.
WARNING: Starting an incorrectly wired hot tub could cause severe damage
to the mechanical equipment or even bodily harm. Have your
licensed electrician verify GFCI (or RCD) wiring with the
diagrams on pages 10-20 prior to starting the hot tub or call the
technical support line at 727.573.9611.
Caution: Failure to abide by specifications listed may result in damage to the
equipment and will void the warranty.
All hot tubs must be wired with the appropriately sized wiring. Failure to do so will
cause equipment damage and will not be covered under your warranty.
All hot tubs must be over current protected with a built-in GFCI (or RCD) in the
service panel.
Volts
Freq.
Model
(V)
(Hz)
LE 852, LE 850,
240
60
LE 744, LE 742
LE 630
240
60
Table 2 – Domestic Wire Size Chart
Volts
Rating
Model
(V)
(A)
LE 852, LE 850,
220-
1x32
LE 744, LE742,
240
2x16
LE 630
Table 3 – Export (Overseas) Wire Size Chart
WARNING: Disconnect electrical power before servicing. Before obtaining
access to terminals, all supply circuits must be disconnected.
WARNING: Test the GFCI (or RCD) before each use.
*
Wire size may need to be reduced at GFCI to fit into the breaker
Solid copper
Wire size may need to be reduced at GFCI to fit into the breaker
§
Solid copper
Rating
GFCI
Wire size from GFCI
(A)
(A)
to Main Panel
6-3 plus ground (up to 130')
48
60
4-3 plus ground (up to 230')
2-3 plus ground (up to 360')
40
50
RCD
Wire size from RCD
(A)
to Main Panel
IEE Wire
3x4 mm
Regulation
5x1.5 mm
Page 9